OPERATIONS
Activation of the camera from a Monitor:
1. The CCTV camera can be viewed on any of the KC monitors in the system by pressing the MONITOR button.
When the video is activated, the audio door station will be activated to transmit audio to the monitor station. To
initiate 2-way audio with the outdoor location, pick up the handset and speak. When the handset is hung up, audio
and video will turn off.
2. To turn the monitor off, press the MONITOR button again. Otherwise, it will automatically time out after
approximately 30 seconds.
Activation of a camera by the Audio Door Station:
1. When the call button is pressed on the JA-D door station, the monitor will turn on with the image from the CCTV
camera, and the chime will sound. The monitor will stay on for approximately 30 seconds if not answered.
2. Pick up the handset to answer, and hang up to conclude. Conversation will automatically turn off in approximately
2-1/2 minutes if handset is not hung up.
Interfacing Video with Other Systems:
1. VIDEO OUT connection simply passes the composite video signal on to a standard CCTV system, such as a
monitor, input on a switcher, or DVR. This video signal is live as long as the camera is powered. When using this
feature, set the 75 OHM switch to the OFF position.
2. RELAY connection provides a normally open contact closure that can be connected to an external system. This
contact will be closed whenever the Aiphone system is turned on. This can be wired into a record input on a DVR or
any other external device that needs to be notified when the video and audio is activated to the Aiphone monitor.
SPECIFICATIONS:
Power: Supplied by KC Monitor
Video Input & Output: Composite 1V Peak-to-Peak, NTSC
Connector: BNC
Audio Door input: Use JA-D surface mount door station only
Relay: Normally open output
Wire: 18AWG, 2-conductor, non-shielded, solid or stranded
Wiring distance: Max. 330 from KCW-M to KC-1MRD or KC-1GRD
Dimensions: 1-5/8"H x 7"W x 4"D
Note:
Only information pertaining to the connection and operation of the KCW-M and devices interfacing with it are included
here. For complete installation, wiring, and operational information about the KC system, please refer to the
Installation Manual included with the monitor.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device , pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to
try and correct the interference by one or more of the following measures:
— Reorient or locate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
FCC Class B Verification