Avanti K-600HW Security Camera User Manual


 
4.2 Setting Up Zone Attributes.
Set-up Zone Attributes menu is entered from the
Engineers menu, by pressing Key 2.
Each of the zones has 9 Attributes that dictate its
function, that are fixed regardless of what the program
set-up has.
On entering the set-up Zone Attributes menu, the Day
LED will flash, along with all 8 zone LED’s. This is to
prompt the engineer to select the zone number for
which to set the attributes.
Once the zone number is entered, the Day LED will stop
flashing and the zone LED’s will be lit according to the
zone attributes that are selected. The attributes are as
follows:
Zone LED 1 – On for Chime. (Key 1)
Zone LED 2 – On for OMIT. (Key 2)
Zone LED 3 – On for double knock. (Key 3)
Zone LED 4 – On for normally open loop. (Key 4)
Zone LED 5 – On for Fire Zone. (Key 5)
Zone LED 6 – On for Doorbell. (Key 6)
Zone LED 7 – Not Used.
Zone LED 8 – On for zone disabled. (Key 8)
Tamper LED – On for Utility output A. (Key 9)
PA LED – On for Utility output B. (Key 0)
Pressing the Key number that represents the LED number
will toggle that attribute.
Press A To Accept / Press B To Abort the changes.
This will then return the engineer back to the Engineers
Menu.
4.3 Setting Up the Exit timer.
Set-up Exit Timer menu is entered from the Engineers
menu by pressing Key 3.
The Exit timer may be programmed from 0 seconds to 99
seconds.
On entering the set-up Exit timer menu, the Day LED will
be extinguished, and Zone 1 & 2 LED’s will light, to
prompt for a 2-digit number between 00 and 99 for the
Exit time in seconds. Once the 2-digit time has been
entered, the PA and TAMPER LED will flash prompting
the engineer to:
Press A To Accept / Press B To Abort the changes.
4.4 Setting Up the Entry timer.
Set-up Entry Timer menu is entered from the Engineers
menu, by pressing Key 4.
The entry timer may be programmed from 0 seconds to
99 seconds.
On entering the set-up Entry Timer menu, the Day LED
will be extinguished, and Zone 1 & 2 LED’s will light, to
prompt for a 2-digit number between 00 and 99 for the
Entry time in seconds. Once the 2-digit time has been
entered, the PA and TAMPER LED will flash prompting
the engineer to:
Press A To Accept / Press B To Abort the changes.
4.5 Setting Up the Bell Active timer.
Set-up Bell Active Timer menu is entered from the
Engineers menu, by pressing Key 5.
The Bell Active Timer may be programmed from 0 Minutes
to 99 Minutes.
On entering the set-up Bell Active Timer menu, the Day
LED will be extinguished, and zone 1 & 2 LED’s will light,
to prompt for a 2-digit number between 00 and 99 for the
Bell Active time in minutes. Once the 2-digit time has
been entered, the PA and TAMPER LED will flash
prompting the engineer to:
Press A To Accept / Press B To Abort the changes.
4.6 Setting Up the Bell Delay timer.
Set-up Bell Delay Timer menu is entered from the
Engineers menu, by pressing Key 6.
The Bell Delay Timer may be programmed from 0 Minutes
to 99 Minutes.
On entering the set-up Bell Delay Timer menu, the Day
LED will be extinguished, and zone 1 & 2 LED’s will light,
to prompt for a 2-digit number between 00 and 99 for the
Bell Delay time in minutes. Once the 2-digit time has been
entered, the PA and TAMPER LED will flash prompting
the engineer to:
Press A To Accept / Press B To Abort the changes.
4.7 Programming Access codes.
Programming Access Codes is entered from the Engineers
menu by pressing Key
7
Once the Programming Access codes menu has been
entered then the Access code to be changed must be
selected. The Day LED and zone LED’s 1 to 7 will flash to
prompt the selection of access codes 1 to 7. The access
codes are selected as follows:
Press 1 To Program User Access code 1.
Press 2 To Program User Access code 2.
Press 3 To Program User Access code 3.
Press 4 To Program User Access code 4.
Press 5 To Program the Holiday code.
Press 6 To Program the Manager code.
Press 7 To Program the Engineer code.
Once the Access code to change has been selected, the
Day LED will light constantly, and zone LED’s 1 to 4 will
light to prompt for the 4 digit access code to be entered.
For every key pressed, 1 zone LED will be extinguished,
indicating the number of digits left to enter of the access
code.
Once all 4 digits of the access code have been entered, all
of the zone LED’s will be extinguished, and the PA and
Tamper LED’s will be flashing.
Press A To Accept / Press B To Abort the changes.
4.8 Setting Up the Service timer.
Set-up Service Timer menu is entered from the Engineers
menu by pressing KEY 8.
The service timer is pre-set to 900 closings. The engineer
has the option of:
1. Enable or disabling the service timer.
2. Resetting the service timer.
On entering the service timer menu the zone LED’s have
the following meaning:
LED 1 Service Timer enabled.
LED 2 Service Timer disabled.
LED 3 Service Timer Expired.
Press 1 To Enable the service timer.
Press 2 To Disable the service timer.
Press 3 To Reset and enable the service timer.
Once a key has been pressed, there will be an
acknowledgement bleep, and then the panel will be
returned back to the engineers menu.