11-5
Cisco ONS 15600 Reference Manual, R7.2
Chapter 11 Alarm Monitoring and Management
11.2.3 Conditions Window
Figure 11-2 Select the Affected Circuits Option for an Alarm
When the user selects the Select Affected Circuits option, the Circuits window opens to show the circuits
that are affected by the alarm.
11.2.3 Conditions Window
The Conditions window displays retrieved fault conditions. A condition is a fault or status detected by
ONS 15600 hardware or software. When a condition occurs and continues for a minimum period, CTC
raises a condition, which is a flag showing that this particular condition currently exists on the
ONS 15600.
The Conditions window shows all conditions that occur, including those that are superseded by alarms.
For instance, if a network problem causes two alarms, such as LOF and LOS, CTC shows both the LOF
and LOS conditions in this window. Having all conditions visible can be helpful when troubleshooting
the ONS 15600. If you want to retrieve conditions that obey a root-cause hierarchy (that is, LOS
supersedes and replaces LOF), you can exclude the same root causes.
Fault conditions include reported alarms and Not Reported or Not Alarmed conditions. Refer to the
trouble notifications information in the Cisco ONS 15600 Troubleshooting Guide “Alarm
Troubleshooting” chapter for more information about alarm and condition classifications.