Cisco Systems ONS 15600 Security Camera User Manual


 
A-6
Cisco ONS 15600 Reference Manual, R7.2
Appendix A Hardware Specifications
A.2.2 SSXC Specifications
A.2.2 SSXC Specifications
Table A-4 shows the SSXC card specifications.
A.2.3 OC48/STM16 LR/LH 16 Port 1550 Specifications
Table A-5 shows the OC48/STM16 LR/LH 16 Port 1550 card specifications.
Table A-4 SSXC Card Specifications
Specification Type Description
Cross-connect Connection setup time: 7 microseconds
Latency: 0.5 microseconds
Operating temperature 23 to 122 degrees Fahrenheit (–5 to +50 degrees Celsius)
Operating humidity 5 to 95%, noncondensing
Dimensions Height: 16.50 in. (419 mm)
Width: 2.36 in. (60 mm)
Depth: 18.31 in. (465 mm)
Card weight: 5.0 lb (2.27 kg)
Compliance When installed in a system, ONS 15600 cards comply with these safety
standards: UL 60950, CSA C22.2 No. 950, EN 60950, IEC 60950
Table A-5 OC48/STM16 LR/LH 16 Port 1550 Card Specifications
Specification Type Description
Line Bit rate: 2.49 Gbps
Code: Scrambled nonreturn to zero (NRZ)
Fiber: 1550 nm single-mode
Loopback mode: Facility
Connectors: OGI
Compliance: SONET Telcordia GR-253
Transmitter Max. transmitter output power: +3 dBm
Min. transmitter output power: –2 dBm
Center wavelength: 1500 nm to 1580 nm
Nominal wavelength: 1550 nm
Transmitter: Distributed feedback (DFB) laser
Note
The Cisco Transport Controller (CTC) Maintenance > Transceiver
tab shows the optical power transmitted (OPT) levels. CTC might
show OPT levels at 1 dBm more or less than the actual card OPT
level.