Dynex DX-DA100502 Camcorder Accessories User Manual


 
Troubleshooting
13
ABNORMAL BATTERY DETECTION
Your charger detects an abnormal battery pack by sensing the voltage. If it is too
high or too low, or if the battery pack does not reach full charge status within 8
hours of charging, the charger stops the operation immediately and indicate the
abnormal condition by flashing both the power and battery status indicator LEDs.
Normal operation resumes when the faulty battery is removed.
Troubleshooting
* To determine if the battery is overcharged or defective, place it on the camcorder
or digital camera and turn it on. If the camcorder or digital camera does not turn
on, the battery is probably defective. If the camcorder or digital camera does not
operate, leave the power turned on for 30+ minutes, then remove the battery and
put it on the charger. The charger should go into charge mode, indicated by the
green blinking charge status indicator.
Maintenance
If the charger must be cleaned, make sure it is unplugged, and then wipe the body
of the charger with a clean cloth lightly dampened with mild detergent. To clean
the metal contacts, use a clean cloth lightly dampened with rubbing alcohol.
Problem Possible causes and solutions
No indicator lights
Confirm that the AC Adapter is firmly connected at
both ends (wall and power input jack)
Confirm that the power outlet is functioning normally
Confirm that the car cord is firmly connected at both
ends (cigarette lighter socket and power input jack)
Confirm that the cigarette lighter socket is
functioning normally
Power light only
The battery is fully charged *
The battery is mounted incorrectly, remove and
remount the battery
Clean the battery and charger contacts
The battery may be defective*
Power and battery status LEDs both blinking Defective battery*
Hissing noise while charging Normal operation due to advance switching
circuitry
Dynex DX-DA100501 camcorder battery charger - combined.fm Page 13 Friday, October 28, 2005 2:54 PM