PRELIMINARY
1.7 2K/4K TDI Camera Timing Diagram
Note: Timing diagram not to scale
2K TDI LVDS
Strobe period :40 nS
LVAL set-up time :20 nS
Line period (min.) :21.8 uS
Blanking :0.8 uS
ExSync min pulse width :120 ns
4K TDI LVDS
Strobe period :40 nS
LVAL set-up time :20 nS
Line period (min.) :43.1 uS
Blanking :2.15 uS
ExSync min pulse width :120 ns
Fairchild Imaging • CAM/CCD-2KLV.TDI & CAM/CCD-4KLV.TDI Line Scan Camera User’s Manual • Rev 073004 • 11 of 38