Heath Zenith SH-5512 Home Safety Product User Manual


 
© 2008 HeathCo LLC 598-1160-03
DualBrite
®
Twin Halogen
Motion Sensing Light
Features
DualZone™ Technology.
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Bulb Saver™ - Extends bulb life by up to 4x standard
bulbs. Lights bulb to full bright in under 2 seconds.
DualBrite
®
Timer.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
Package Contents
Requirements
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
Cover
Plate
Light Control
Sensor
3 Wire
Connectors
Gasket
6 Mounting
Screws (3 sizes)
Mounting Bolt
Mounting Strap
Rubber Plug
OPERATION
* resets to Auto Mode at dawn.
TEST
Put ON-TIME switch
on the sensor bottom
to TEST and the Dual-
Brite
®
switch OFF.
MANUAL MODE
ON-TIME
TEST 1 5 20
... back on.
AUTO
1 Second OFF
then...
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.
Light Shield
Plastic Hanger
2 Halogen Bulbs
Put the ON-TIME switch in the 1, 5,
or 20 minute position.
Mode: On-Time Works: Day Night
Test
5 Seconds x x
Auto
1, 5, or 20 Min x
Manual
To Dawn* x
Accent
3, 6 Hr, to Dawn x
TEST 1 5 20
ON-TIME DualBrite
®
Off 3 6 Dusk to
Dawn
Meets the ENERGY STAR
®
guidelines
when DualBrite
®
function is off and
ON-TIME is 1 or 5 minutes and when
used with 120 W Max bulbs.
Model SH-5512