Ikelite 6871.45 Digital Camera User Manual


 
17
18
19
OOppttiioonnaall AAcccceessssoorriieess
LLeeaadd WWeeiigghhtt ##00990066..5588
The buoyancy of the system will depend on the size and
number of strobes used, as well as the weight of the camera.
Ideally the system should be slightly negative in the
environment in which it will be used. If you need to add weight
to the system, an optional lead weight is available. To add the
lead weight, remove the (2) screws from the bottom of the
aluminum tray. Place the lead weight into the pocket of the
aluminum tray and reattach.
IIkkeelliittee LLuubbee ##00118844..11
PPoorrtt OOrriinngg ##00110055
HHoouussiinngg BBaacckk OOrriinngg ##00113322..5599
While both the Port and Back o’rings should last quite some time
it is best to carry a spare in case one becomes damaged or lost.
SSttoorriinngg tthhee HHoouussiinngg
When the housing is going to be stored for a prolonged period,
it should be soaked in a mild soap solution, rinsed, and dried
thoroughly. Remove the back and port from the housing.
Remove the back and port o’rings, lightly lubricate them, and
then place them in a plastic zip-lock bag. Place the plastic bag
inside the housing for storage. Operate the push buttons
periodically.
20
P
P
r
r
e
e
-
-
D
D
i
i
v
v
e
e
Y
Y
o
o
u
u
r
r
S
S
y
y
s
s
t
t
e
e
m
m
It is recommended that you take the complete system into a
s
wimming pool before use in open water. This will give you a
chance to become familiar with the handling and operation of
your housing and strobe(s).
U
U
s
s
i
i
n
n
g
g
E
E
x
x
t
t
e
e
r
r
n
n
a
a
l
l
S
S
t
t
r
r
o
o
b
b
e
e
s
s
C
C
o
o
n
n
t
t
.
.
UUssiinngg IIkkeelliittee NNoonn--DDSS SSuubbssttrroobbeess ((SSuubbssttrroobbee 5500,, 110000AA,,
220000,, 440000)) wwiitthh tthhiiss HHoouussiinngg..
The Conversion Circuitry is automatically disabled when used
with a Non-DS Substrobe. These Substrobes can be used in their
manual mode utilizing any power settings provided on the
Substrobe.
UUssiinngg NNoonn IIkkeelliittee SSttrroobbeess wwiitthh tthhiiss HHoouussiinngg..
The Conversion Circuitry is automatically disabled when used
w
ith a Non Ikelite Strobe. These strobes can be used in their
manual mode utilizing any power settings provided on the strobe.
LLuubbrriiccaannttss
1. Ikelite provides silicone lubricant with the housing. We
recommend that you use only Ikelite lubricant. Other brands
may cause the o’ring to swell and not seal properly.
2. Use only enough Ikelite lubricant to lightly cover control shafts
and o’rings. Wipe off any excess lubricant with a clean cloth.
Lubricant is not a sealant and is used to reduce friction.
Excessive lubricant can collect sand and dirt which may
interfere with proper sealing.
NNoottee::
Lubricant is not needed on the main housing o’ring to
maintain a housing seal, however, lightly lubricating this o’ring
can extend it’s life and aid in seeing a good housing seal. Too
much lube can attract debris increasing the potential for a leak.
CCAAUUTTIIOONN::
N
N
e
e
v
v
e
e
r
r
u
u
s
s
e
e
s
s
p
p
r
r
a
a
y
y
l
l
u
u
b
b
r
r
i
i
c
c
a
a
n
n
t
t
s
s
a
a
s
s
t
t
h
h
e
e
p
p
r
r
o
o
p
p
e
e
l
l
l
l
a
a
n
n
t
t
i
i
n
n
g
g
r
r
e
e
d
d
i
i
e
e
n
n
t
t
c
c
a
a
n
n
c
c
a
a
u
u
s
s
e
e
t
t
h
h
e
e
p
p
l
l
a
a
s
s
t
t
i
i
c
c
h
h
o
o
u
u
s
s
i
i
n
n
g
g
t
t
o
o
c
c
r
r
a
a
c
c
k
k
.
.
MMaaiinntteennaannccee
Your Ikelite Housing should be given the same care and attention
as your other photographic equipment. In addition to normal
maintenance, we recommend your housing be returned to Ikelite
(every 2-3 years or 50 dives), to be checked and pressure tested.
1.
DDoo NNoott
leave the camera and housing in direct sunlight for
prolonged periods. Heat may damage the camera.
2.
DDoo NNoott
ship the camera in the housing.
3. Before using the housing, always check the tightness of the
sseett
ssccrreeww
in each control knob.
Check each
ccoonnttrrooll ggllaanndd
penetrating the housing to make sure
they are tight. There is a slight chance that either could vibrate
loose during travel.
4. Keep the back and port o’ring clean and lightly lubricated. To
lubricate, remove the o’ring from the back. Put a small amount
of lkelite lubricant on your fingers. Pull the o’ring through your
fingers to apply a light coating of lubricant. Only apply enough
lubricant to make the o’ring feel slick.
DDoo NNoott ssttrreettcchh tthhee oorriinngg
.
This light coating of lubricant will help to keep the o’ring from
drying out and will help to show a dark sealing line when the
housing back is properly sealed.
5. Keep the area where the o’ring fits and the sealing surface clean.
6. Rinse the housing exterior thoroughly in fresh water after each
salt water use. Depress push buttons several times during rinse.
Dry with a soft cloth. Dry port to eliminate water spotting.
After several uses in salt water, soak the housing in a mild soap
solution, rinse, and dry.
7. Although not recommended, if it is necessary to remove a
housing push button,
DDoo NNoott
re-use the E-clip. Contact Ikelite
for replacement E-clips (part #0319.12).
CCAAUUTTIIOONN::
N
N
e
e
v
v
e
e
r
r
u
u
s
s
e
e
s
s
p
p
r
r
a
a
y
y
l
l
u
u
b
b
r
r
i
i
c
c
a
a
n
n
t
t
s
s
a
a
s
s
t
t
h
h
e
e
p
p
r
r
o
o
p
p
e
e
l
l
l
l
a
a
n
n
t
t
i
i
n
n
g
g
r
r
e
e
d
d
i
i
e
e
n
n
t
t
c
c
a
a
n
n
c
c
a
a
u
u
s
s
e
e
t
t
h
h
e
e
p
p
l
l
a
a
s
s
t
t
i
i
c
c
h
h
o
o
u
u
s
s
i
i
n
n
g
g
t
t
o
o
c
c
r
r
a
a
c
c
k
k
.
.
CCoonnttrrooll MMaaiinntteennaannccee
Ikelite controls are designed to provide years of reliable service
with minimal maintenance.
1. Push button controls require no maintenance other than rinsing
in fresh water after saltwater use. If a push button control
becomes difficult to push, or if it sticks when depressed, soak
the housing in luke warm fresh water. After a few minutes
operate the push button. If this does not correct the problem,
return the housing to Ikelite for maintenance.
2. Some of the controls have long shafts. These controls can be
pulled out, exposing the shaft (see drawing).
To lubricate the control, gently pull on the knob until the
stainless steel shaft is exposed. Lightly lubricate the shaft, then
move the shaft in and out several times. This will lubricate the
x’ring in the Ikelite control gland. This should be done before
using the housing after a prolonged storage period, or once a
week when the housing is in constant use.
housing
lubricate shaft
pull out to