To prepare the port for installation remove the port o’ring and
l
ightly lubricate it The port seal is a sidetoside seal and
requires the o’ring to be lightly lubricated for easy installation
Put a small amount of lubricant on your fingers and draw the
o’ring through your fingers to lightly lubricate it Do not stretch
the o’ring Check that the lip of the port where the o’ring fits
and the sealing surface on the housing are clean Place the port
with o’ring into the housing’s port opening Press the port
f
irmly and evenly into the port opening until you feel the port
slip into place Continue to push down on the port and push
e
ach port lock forward until it clicks into place It may help to
slightly rotate the port as you push in on the port lock When
the port lock clicks into place the Release Button will drop
down against the port lock
Check around the perimeter of the port seal to see that the
o
’ring is properly sealed and not extruded
T
T
o
o
R
R
e
e
m
m
o
o
v
v
e
e
P
P
o
o
r
r
t
t
To remove the port lift up on each Release Button and slide the
port lock away from the port
P
P
o
o
r
r
t
t
S
S
e
e
a
a
l
l
I
I
n
n
s
s
i
i
d
d
e
e
V
V
i
i
e
e
w
w
If the port is installed before the camera is
inserted into the housing look on the inside of
the housings at the port seal Check to see that
the o’ring is properly sealed as shown in
figure  and not extruded as shown in figure 
10
1
1
U
U
s
s
i
i
n
n
g
g
E
E
x
x
t
t
e
e
r
r
n
n
a
a
l
l
F
F
l
l
a
a
s
s
h
h
U
U
s
s
i
i
n
n
g
g
I
I
k
k
e
e
l
l
i
i
t
t
e
e
D
D
S
S
S
S
u
u
b
b
s
s
t
t
r
r
o
o
b
b
e
e
s
s
This housing incorporates Conversion Circuitry which provides
O
lympus TTL flash when used with any Ikelite DS Substrobe
Requires Sync Cord  for single DS Substrobe or
 for dual DS Substrobes
U
U
s
s
i
i
n
n
g
g
N
N
o
o
n
n
D
D
S
S
S
S
u
u
b
b
s
s
t
t
r
r
o
o
b
b
e
e
s
s
Non DS Substrobe can be used but will only operate in manual
m
ode and not provide the TTL functions of the coversion
circuitry
U
U
s
s
i
i
n
n
g
g
O
O
t
t
h
h
e
e
r
r
M
M
a
a
n
n
u
u
f
f
a
a
c
c
t
t
u
u
r
r
e
e
r
r
s
s
S
S
t
t
r
r
o
o
b
b
e
e
s
s
Other strobes can be used but will only operate in manual
mode and not provide the TTL functions of the conversion
c
ircuitry Mounts and sync cords for Nikonos and sync cords for
Inon or Sea & Sea strobes are available
S
S
t
t
r
r
o
o
b
b
e
e
A
A
r
r
m
m
s
s
This housing offers two types of arm mounting systems The top
of the rubber handles utilize Ikelite’s quickrelease arm available
with the SAR Arm system
The bottom of the rubber handles have a wing nut that accepts
the Ikelite Tray Mount The Tray Mount comes with the Ikelite
SA Arm system and the SAT Arm system
P
P
r
r
e
e
D
D
i
i
v
v
e
e
Y
Y
o
o
u
u
r
r
S
S
y
y
s
s
t
t
e
e
m
m
It is recommended that you take the complete system into a
swimming pool before use in open water This will give you a
chance to become familar with the handeling and operation of
your housing and strobe(s)
O
O
p
p
t
t
i
i
o
o
n
n
a
a
l
l
A
A
c
c
c
c
e
e
s
s
s
s
o
o
r
r
i
i
e
e
s
s
L
L
e
e
a
a
d
d
W
W
e
e
i
i
g
g
h
h
t
t
The buoyancy of the system will depend on the size and
number of strobes used as well as the weight of the camera
Ideally the system should be slightly negative in the
environment in which it will be used If you need to add weight
to the system an optional lead weight is available To add the
lead weight remove the () screws from the bottom of the
aluminum tray Place the lead weight into the pocket of the
aluminum tray and reattach
I
I
k
k
e
e
l
l
i
i
t
t
e
e
L
L
u
u
b
b
e
e
P
P
o
o
r
r
t
t
O
O
r
r
i
i
n
n
g
g
H
H
o
o
u
u
s
s
i
i
n
n
g
g
B
B
a
a
c
c
k
k
O
O
r
r
i
i
n
n
g
g
While both the Port and Back o’rings should last quite some time
it is best to carry a spare in case one becomes damaged or lost
S
S
t
t
o
o
r
r
i
i
n
n
g
g
t
t
h
h
e
e
H
H
o
o
u
u
s
s
i
i
n
n
g
g
When the housing is going to be stored for a prolonged period it
should be soaked in a mild soap solution rinsed and dried
throughly Remove the back and port from the housing Remove
the back and port o’rings lightly lubricate them and place them
in a plastic ziplock bag Place the plastic bag inside the housing
for storage
12
C
C
h
h
o
o
o
o
s
s
i
i
n
n
g
g
a
a
P
P
o
o
r
r
t
t
D
D
O
O
M
M
E
E
P
P
O
O
R
R
T
T
 
Wide angle mm to mm
or lens up to cm (") in length

Nikon  & mmD lenses
 Lens cm (")
Lens cm (")


Lens cm (")


Nikkor mm lens only
 Lens cm (")
Some zoom lenses may require the addition of a diopter closeup lens
(Available from camera store)
SUPERWIDE DOME PORT
Superwide lens ° to ° Not compatible with the SLRMD housing due
to vignetting
 Lens up to cm (")
•With the lens on the camera extended to
full length measure from front of camera
to face of lens
•Select the appropriate port based on the
lens type and length
•Maximum lens diameter accommodated is
cm (")
•Maximum lens diameter when using
zoom or focus clamp cm (")
Measure
M
M
e
e
a
a
s
s
u
u
r
r
i
i
n
n
g
g
a
a
L
L
e
e
n
n
s
s
t
t
o
o
c
c
h
h
o
o
o
o
s
s
e
e
a
a
p
p
o
o
r
r
t
t