Tools Required
Anti-static
wrist strap
Phillips*
screwdriver
Caution
Observe normal ESD
[Electrostatic Discharge]
procedures during system
integration to avoid possible
damage to compute module and/or
other components.
Warning
Installation and service of
this product to be performed
only by qualified service
personnel to avoid risk of injury from
electrical shock or energy hazard.
Warning
Read all caution and safety
statements in this document
before performing any of the
instructions. Also see the Intel
®
Server Board and Server Chassis
Safety Information document at:
http://support.intel.com/support/
motherboards/server/sb/cs-010770
.htm for complete safety information.
4
Install System in Rack (Optional)
Storage Controller
A
B
Main Cooling Module
A
B
Power Supply Module
A
B
Ethernet Switch Module
A
B
Management Module
A
B
Chassis Back
I/O Cooling Module
A
B
Chassis Front
4(b) Finishing Up
THREE PEOPLE ARE REQUIRED TO LIFT THE
SYSTEM. If handles are present, remove the rear
handles prior to setting system onto slide rails.
Remove the front handles prior to sliding system
all the way into rail assembly.
Secure system to rack per rail kit installation
instructions.
Re-install all power supply modules, cooling modules,
the storage controller, the management module and the
Ethernet switch module. See the Intel® Modular Server
System MFSYS25 User Guide
for complete instructions on installing modules.
To re-install a power supply or cooling module:
■
Slide module into appropriate module
bay until retention latch engages.
To re-install a management module, storage controller
or Ethernet switch module:
■
Ensure retention lever is released and
rotated out and away from module.
■
Slide module into appropriate module
bay until bottom of retention lever
engages with bay.
■
Rotate retention lever in toward module
until it latches.
4(a) Preparation
Prepare rail system for rack mounting. Refer to the
Rail Kit Install Guide that is included with your rail
kit for instructions on assembling the kit.
Remove all modules from the Intel® Modular
Server System prior to lifting system into rack. This
includes all cooling modules, all power supply
modules, the management module, the Ethernet
switch module, and the storage controller. Refer to
adjacent illustrations for module location. See the
Intel® Modular Server System MFSYS25 User
Guide for complete instructions on removing modules.
To remove a power supply or cooling module:
Press retention latch to the left to
release module from module bay.
Slide module out of module bay.
To remove the management module, storage controller
or Ethernet switch module:
Press retention latch to the left to release
module from module bay.
Rotate retention lever out and away from
module.
Slide module out of module bay.
A
B
A
B
C
Three people ARE REQUIRED to lift the empty
system into the rack assembly. DO NOT lift
system while fully loaded.
Rear handles MUST BE removed prior to setting
system on rack rails. The profile of the handles
interferes with rack rails.
Front handles MUST BE removed prior to sliding
system all the way into rail assembly.
3
Install Pedestal
Feet (Optional)
Remove temporary handles if
present.
Lay chassis down horizontally.
Remove pedestal feet from strip
of sticky paper.
Affix one foot to each of the six
indent locations on the bottom
side of the chassis.
A
B
C
D
2
Install Temporary Handles (Optional)
A
A
A
A
B
B
Insert handle tabs into chassis slots.
Tighten captive screws.
A
NOTE: Handles are provided as
temporary devices to assist in
removing system from packaging
and for initial configuration.
DO NOT lift system
by power supply or
cooling module
handles.
1
Unpackaging
System
As packaged, the system
weighs 100 lbs. Install
temporary handles (see
Step 2) before lifting system
from shipping box.
Do not lift system from
packaging by power supply
or cooling module handles.
A minimum of three people
are required to lift system as
packaged.
Temporary handles will need
to be removed if system is
to be used in the pedestal or
rackmount configurations.
Package Contents
■ Intel® Modular Server System MFSYS25
■ Intel® Gigabit Ethernet Switch AXXSW1GB
plus one filler blank
■ Intel® Storage Controller plus one filler blank
■ Intel® Management Module
■ 2 power supply modules
■ 2 power supply blanks
■ 1 I/O cooling module
■ 2 main cooling modules
■ 5 compute module blanks
■ 2.5-inch SAS shared hard drive bay
■ 14 hard drive carriers
■ Resource CD
■ This document
■ Attention Document
■ Rail kit
■ 6 pedestal feet
If you are not familiar with ESD (Electrostatic Discharge) procedures
used during system integration, please see the Intel
®
Modular Server
System MFSYS25 User Guide, available at
http://support.intel.com/support/motherboards/server/MFSYS25
Read all cautions and warnings before starting your server system integration.
Thank you for buying an Intel
®
Modular Server System.
The following information will help you
assemble your Intel
®
Modular Server System MFSYS25
and install components.
This guide and other supporting documents
are located on the web at:
http://support.intel.com/support/motherboards/server/MFSYS25
Intel
®
Modular Server System
MFSYS25
Quick Start User's Guide