JVC RM-HP250DE Camera Accessories User Manual


 
16
1.
Press the SHUTTER control to activate the shutter speed
variation facility, which is indicated by the lighting of the
SHUTTER light.
2.
Turn the SHUTTER control to vary the shutter speed. The
LCD display shows the shutter speed during the adjust-
ment operation.
The shutter speed can be adjusted in either STEP mode
for adjustments in steps or in VARIABLE mode for fine
adjustments.
REF.
: Item “5A: SHUTTER” on page 25.
“Operable Camera Features” on page 29.
STEP : Change the shutter speed with the fixed values.
The fixed values differ depending on the VIDEO
FORMAT of the camera.
VARIABLE: Use this mode when shooting an image on a
computer monitor, etc.
(Variation range: approx 1/50 to 1/2000)
The VARIABLE function is unavailable when connected
to GY-HD250/GY-HD251.
Shutter Speed Adjustment
Turning the SHUTTER control can vary the shutter speed of the camera. The LCD display shows the
shutter speed during the adjustment operation.
Camera Adjustments
M
FULL AUTO F1
SHUTTER
GAIN
F2
F3
MENU/SHUTTER GAIN
P
R
STEP
SHUTTER
MENU
PUSH-ON
DOWN UP
VARIABLE
PUSH-ON
HIGH
LOW
MID
DOWN UP
F4
BARS
1/1000
SHUTTER control
SHUTTER light
When the FAS (Full Auto Shooting) is ON, the shutter
speed becomes EEI. However, the shutter speed is OFF
in the Lolux mode.
When FAS is ON, the SHUTTER control cannot be used
to vary the shutter speed.
When ALC+EEI is ON, the shutter speed becomes EEI. At
this time, the SHUTTER control cannot be used to vary the
shutter speed.
NOTE
Values that are not available on the camera cannot
be set on this unit.
REF.
: “Operable Camera Features” on page 29.
The shutter speed displayed on the RM-HP250 may
be slightly different from the actual shutter speed of
the camera.
NOTE
Format STEP value
HDV-HD60P 1/100, 1/250, 1/500, 1/1000,
HDV-HD30P 1/2000, 1/4000, 1/10000
DV-60I
HDV-HD24P
DV-24P
DV-24PA
HDV-HD50P 1/120, 1/250, 1/500, 1/1000,
HDV-HD25P 1/2000, 1/4000, 1/10000
DV-50I
DV-25P