JVC RM-P2580 Camera Accessories User Manual


 
22
Terminal Name
AUTO
I/O 1 to 8
UNIT ALARM
CAMERA SW
Condition
When 8 SEL OUT is set
• I/O 1 to 8 correspond to
cameras 1 to 8.
When 16 SEL OUT is set
• I/O 1 to 16 correspond to
cameras 1 to 16.
8ALM OUT
• I/O 1 to 8 correspond to
cameras 1 to 8.
16ALM OUT
• I/O 1 to 16 correspond to
cameras 1 to 16.
B MODE
Signals
The MAKE signal is output for between 500 ms and 1000 ms duration
in the following cases.
Power OFF ON.
AUTO SEQUENCE (AUTO button OFF ON)
When the SW-D7000/SW-D8000 is designated on the SERIAL-2 of
the equipment connected, the MAKE signal can be output by press-
ing the AUTO button.
The MAKE signal is output for between 500 ms and 1000 ms duration
in the following cases.
When the AUTO button is turned OFF from ON status, the MAKE
signal is output to the Camera No. terminal corresponding to the
camera which outputs the signal to MONITOR OUTPUT.
Each time when the camera is selected while the AUTO button is
OFF, the MAKE signal is output to the Camera No. terminal corre-
sponding to the camera selected.
With the PRIORITY item set to ALARM, when there is an Alarm
input while the AUTO button is OFF, the MAKE signal is output to
the Camera No. terminal corresponding to the camera to which the
Alarm signal is input.
The main signal is output at the terminal corresponding to the number
of the camera which sent the alarm signal.
The MAKE signal is output continuously throughout the alarm period.
The “CAM SWITCH” is permanently OFF. The MONITOR OUTPUT 2
connector always outputs the same video as the MONITOR OUTPUT
1 connector.
4. CONNECTIONS
In B mode in which camera signals are switched by a frame switcher, the DATA I/O outputs are as shown in the following table :
The monitor displays the video that is switched by the frame switcher.
The master monitor displays either a multi-split screen or the menu screen.
The cameras are selected by controlling the frame switcher through the SERIAL-2 connector.
The preset operation, manual operation, AUTO PAN operation and AUTO PATROL operation are individually available for each camera.
Alarm operation with up to 16 alarm inputs is available by using the DATA I/O terminals.
Alarms with up to 64 positions per camera can be handled via the SERIAL-1 connector.
NOTES
MANUAL operation of cameras and the menu operation are available even in the auto mode.
As the frame switcher control signal is not output, the information in the CAMERA display does not change.