JVC TK-C676 Digital Camera User Manual


 
E-8
MONITOR
OUTPUT 1
TO
CAMERA
Remote control unit
RM-P2580
Control signal cable
Coaxial cable
AC 24 V
power supply
AC 24 V
power supply
AC 24 V
power supply
Monitor
Camera 1
Camera 2
Camera 8
TK-C676
TK-C676
TK-C676
MACHINE ID: 01
Switch 8: OFF
(RX TERM)
MACHINE ID: 02
Switch 8: OFF
(RX TERM)
MACHINE ID: 08
Switch 8: ON
(RX TERM)
Connections & Installation
TX
+
A
TX
B
RX
+
C
RX
D
TX
+
Camera 1
CONTROL terminals
Camera 2
CONTROL
terminals
Camera 3
CONTROL
terminals
RX
+
A
RX
B
TX
+
C
TX
D
RM-P2580
terminal
A
TX
B
RX
+
C
RX
D
TX
+
A
TX
B
RX
+
C
RX
D
Connection of the control signal cable
(A twisted pair cable is recommended.)
Power cable
Control signal cable
To AC 24V power supply
To the TO CAMERA connector of the
RM-P2580 and to the next camera
Coaxial cable
To the CAMERA INPUT connector
of the RM-P2580
Duplex display ID No. display
LPROCESS<<>>I INTIA
:--I--PAN
:--I--TILT
DUPLEX ID-01RO T>P COOL
Camera 1 monitor display
at power ON
(ID check procedure
P. 13)
Switch 1
:
Switch 2
:
Switch 4 : ON
Switch 5 : OFF
Switch 7 :
Invalid (Set to OFF.)
Switch 8 :
Figure of 1
Figure of 10
Set it to the same number as the
VIDEO INPUT terminal of the RM-
P2580.
(Example) Camera 1:
Set the figure of 10 to 0 and
figure of 1 to 1.
Set to ON only for the
camera connected at
the end of the control
signal cable.
Set to OFF for all
other cameras.
Machine ID
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
1
2
3
4
6
7
8
5
O
F
F
Invalid (Set to OFF.)
A Multi-Drop Communication System
A system that employs the RM-P2580 as the controller
The following figure shows a system that can accommodate up to eight cameras. (64 positions can be preset per camera.)
Observe the following points when connecting compo-
nents together:
Turn all the components off before proceeding.
Read the instruction manuals of all components before pro-
ceeding.
For the types and lengths of connection cables, see Cable
Connections on page 14.
Do not connect the control signal cables in a loop.
Cable connections
P. 14
(Terminal side of Ceiling Mount)
Switch settings
P. 12
(Setting switches are on the side of the Ceiling Mount)
Each terminal on the camera and the RM-
P2580 is marked A
, B
, C
or D
. In order
to facilitate understanding and to avoid
connection mistakes, it is recommended
to connect the terminals carrying the
same marks.