Panasonic WV-CW480S Security Camera User Manual


 
23
Cautions:
Be sure to connect the GND (grounding)
lead of the camera and grounding termi-
nal of the power supply when using a
24 V AC (WV-CW484F) or 220 V to 240 V
AC (WV-CW480S) power source.
Shrinking the cable-entry seal is a one-
time procedure. Do not shrink the cable
entry seal until it has been ascertained
that unit is functioning.
ONLY CONNECT THIS TO 24 V AC or
12 V DC CLASS 2 POWER SUPPLY.
(WV-CW484F)
To prevent fire or electric shock hazard,
the UL listed wire VW-1 style 1007 should
be used for the cable for Input Terminals.
Do not use a transformer larger than
10 VA.
• Cable Length and Wire Gauge
<WV-CW484F>
24 V AC
The recommended cable length and thick-
ness are shown in the table for reference.
The voltage supplied to the power terminals
of the camera should be within 19.5 V AC
and 28 V AC.
Copper wire
size (AWG)
Length of
Cable
(Approx.)
#24
(0.22 mm
2
)
20
#22
(0.33 mm
2
)
30
#20
(0.52 mm
2
)
45
#18
(0.83 mm
2
)
75
Recommended wire gauge for 24 V AC line.
(m)
Copper wire
size (AWG)
Resistance
/m
#24
(0.22 mm
2
)
0.078
#22
(0.33 mm
2
)
0.050
#20
(0.52 mm
2
)
0.03
#18
(0.83 mm
2
)
0.018
Resistance of copper wire [at 20 °C]
12 V DC
Use the formula below to calculate the power
cable and power supply. The voltage sup-
plied to the power terminals of the camera
should be within 10.5 V DC and 16 V DC.
10.5 V DC V
A - 2(R x I x L) 16 V DC
L : Cable length (m)
R : Resistance of copper wire (/m)
V
A : DC output voltage of power supply
unit
I : DC current consumption (A). See
specifications.
Important: When using 12 V DC power sup-
ply, the optional heater unit is unavail-
able.