PARK TIME
This feature allows the dome to begin a specified operation (scan, preset, or pattern) after a configured period of inactivity.
Park time can be configured from 1 to 720 minutes (12 hours), or set to zero, which disables this feature. The default setting is zero.
Park Action
This feature will define the activity when the dome parks. The following settings are available:
NONE (default): No action.
AUTO SCAN: Dome starts auto scan operation.
RANDOM SCAN: Dome starts random scan operation.
FRAME SCAN: Dome starts frame scan operation.
PRESET 1: Dome goes to preset 1.
PRESET 8: Dome goes to preset 8.
PATTERN 1: Dome runs pattern 1.
PATTERN 2: Dome runs pattern 2.
PATTERN 3: Dome runs pattern 3.
PATTERN 4: Dome runs pattern 4.
PATTERN 5: Dome runs pattern 5.
PATTERN 6: Dome runs pattern 6.
PATTERN 7: Dome runs pattern 7.
PATTERN 8: Dome runs pattern 8.
(Only 27X and 35X models allow PATTERN 2 through PATTERN 8.)
SCAN SPEED
Scan speed is the degrees per second that the dome will pan when in a scan mode. Scan speed is adjustable from 1 to 40 degrees per second
through the camera menu. The default setting is 25 degrees per second.
PRESET FREEZE FRAME
This feature freezes the scene on the monitor when going to a preset. This allows for smooth transition from one preset scene to another. Preset
freeze frame also reduces bandwidth when used with digital network systems such as PelcoNet
and guarantees that blanked areas will not be
revealed when going to a preset.
There are three preset freeze frame settings:
ON: The image on the screen freezes when a preset is called. When the dome reaches the preset, the image is unfrozen and the preset scene is
displayed.
OFF: The image is never frozen.
AUTO (default): Freeze frame is turned on automatically if window blanking is ON. If window blanking is OFF, freeze frame is off.
LIMIT STOPS
Limit stops are configurable stops that limit the pan range of the dome. There must be two limits, a left and a right, to define an area.
There are two types of limit stops:
MANUAL: A manual (joystick) pan operation stops when a limit stop is reached.
SCAN: The dome reverses direction during random, frame, or auto scanning when a limit stop is reached.