Pelco C2444M-C Security Camera User Manual


 
C2443M-C (1/04) 39
(See page 9)
Quick Programming Guide
<Alert>
NOTE: The
Alert
section only applies to Pressurized Spectra III SE dome systems with software
version 1.25 or higher. Spectra III SE systems that are not pressurized or pressurized systems
that do not have dome drive software version 1.25 or higher will not display this menu item.
Software version 1.25 or higher includes the software to monitor temperature, pressure, and
dew point for Pressurized Spectra III SE systems.
Sensors strategically placed inside the pressurized dome system continually monitor pressure,
temperature, and dew point. If internal conditions reach unacceptable levels, an alert message
appears on the screen describing the alert condition. Example: If pressure drops below 1 psig,
“LOW PRESSURE” is displayed on the monitor.
The following system conditions will trigger an alert message:
System Condition Alert Message
Temperature is above 140°F (60°C) HIGH TEMPERATURE
Temperature is below -40°F (-40°C). LOW TEMPERATURE
Pressure is above 11 PSIG. HIGH PRESSURE
Pressure is below 1 PSIG LOW PRESSURE
The difference between the temperature and the dew point is DEW POINT (HIGH
less than or equal to 3°C. HUMIDITY)
The alert message will be repeatedly displayed until the system controller acknowledges the
alert condition by selecting ACK ALERT in the main menu. Once acknowledged, the alert
message changes to the programmed acknowledge action (ACK ACTION). If the alert condition
remains active after a period of time, the alert message reappears on the monitor, restarting the
alert message cycle. This cycle will continue to repeat until the alert condition is resolved.
REPEAT
This setting programs how often an alert message is repeatedly displayed until the system
controller acknowledges the alert condition. The following are the settings for REPEAT:
CONSTANT - The alert message is continuously displayed on the monitor until acknowledged.
15 MIN - The alert message is displayed every 15 minutes for a 15-second duration until
acknowledged.
30 MIN - The alert message is displayed every 30 minutes for a 15-second duration until
acknowledged.
60 MIN - The alert message is displayed every 60 minutes for a 15-second duration until
acknowledged.
REPEAT CONSTANT
ACK ACTION ALWAYS ON
ACTIVATE AUX NO
<CURRENT READING>
RESET ALERT
BACK
EXIT
ALERT
EXIT
SPECTRA III
LANGUAGE ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
BACK
EXIT
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<ALERT>
<CLEAR>
<PASSWORD>
DOME SETTINGS