General Trouble Shooting
COMMON PROBLEMS AND CAUSES
Unit does not charge.
Probable causes:
a. Fuse blown. (Unplug and discharge the unit-Replace fuse.)
b. No line power to unit. (Check line cord and outlet.)
c. Defective unit. (Return for repair.)
Modeling light does not turn on.
Probable causes:
a. Lamp turned off. (Press FULL ON/OFF button until LED
lights.)
b. Lamp burned out. (Inspect and replace, when cool. Replace
with same part number.)
Light flashes by itself without apparent reason.
Probable causes:
a. Defective trigger cord, or trigger cord incorrectly polarized.
b. Bright light falling on photoslave.
c. Poor connection in line cord.
d. Reverse connection on trigger cord connection at camera.
e. Some radio slaves will cause interference. Consult slave
manufacturer.
Trigger cord will not flash unit, but charge indicator shows that the system
has charged.
Probable causes:
a. Defective trigger cord.
b. Defective flashtube. Turn unit off. Wait until discharged (4
hours) and cool, then replace flashtube. (See SERVICE
section of this manual)
Photoslave is not triggering the flash.
Note: The photoslave requires another flash to trigger the unit.
Probable causes:
a. Ambient light may be flooding the photocell.
b. Another light in the studio may be flooding the photocell.
c. The sync jack is being used.
d. Defective unit. Return for repair.