Polycom Ceiling DocCam Camera Lens User Manual


 
Ceiling DocCam II — Appendix
23
Ceiling DocCam II — Appendix
22
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Command List
Command Set Command Command Packet Comments
Address Set Broadcast 88 30 01 FF
IF_Clear Broadcast 88 01 00 01 FF
CommandCancel 81 2p FF p: Socket No.(=1or2)
CAM_Zoom Stop 81 01 04 07 00 FF
Tele (Standard) 81 01 04 07 02 FF
Wide (Standard) 81 01 04 07 03 FF
Tele (Variable) 81 01 04 07 2p FF p=0 (Low) to 7 (high)
Wide (Variable) 81 01 04 07 3p FF
Direct 81 01 04 47 0p 0q 0r 0s FF
pqrs: Zoom Position
CAM_DZoom
On 81 01 04 06 02 FF Digital zoom ON/OFF
Off 81 01 04 06 03 FF
Combine Mode 81 01 04 36 00 FF Optical/Digital
Zoom Combined
Separate Mode 81 01 04 36 01 FF Optical/Digital
Zoom Separate
Tele(Variable) 81 01 04 06 2p FF
p=0 (low) to 7 (high)
Wide(Variable) 81 01 04 06 3p FF
x1/Max 81 01 04 06 10 FF x1/Max Magnification
Switchover
Direct 81 01 04 46 00 00 0p 0q FF pq: D-Zoom Position
CAM_Focus
Stop 81 01 04 08 00 FF
Far (Standard) 81 01 04 08 02 FF
81 01 04 08 03 FF
Far (Variable) 81 01 04 08 2p FF
Near (Variable) 81 01 04 08 3p FF
p=0 (Low) to 7 (high)
Direct 81 01 04 48 0p 0q 0r 0s FF
Auto Focus 81 01 04 38 02 FF
Manual Focus 81 01 04 38 03 FF
Auto/Manual 81 01 04 38 10 FF
One Push Trigger 81 01 04 18 01 FF
Infinity 81 01 04 18 02 FF
Forced infinity
Near Limit 81 01 04 28 0p 0q 0r 0s FF pqrs: Focus Near
Limit Position
Near (Standard)
pqrs: Focus Position
AF ON/OFF
One Push AF Trigger
Stop
81 01 04 06 00 FF
AF Sensitivity Normal
Low
81 01 04 58 02 FF
81 01 04 58 03 FF
AF Sensitivity
High/Low
81 01 08 02 01 FF
Camera Power
81 01 08 01 01 FF Power onOn
81 01 08 01 00 FF Power off
Laser Power On Power on
81 01 08 02 00 FF Power off
Off
Momentary 81 01 08 02 02 XX FF XX=time on from
1 to 10 seconds
Off
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
VISCA Camera-Issued Messages
ACK/Completion Messages
Error Messages
Network Change Message
z0 4y FF
(y:Socket No.)
Returned when the command is accepted.ACK
Completion z0 5y FF
(y: Socket No.)
Returned when the command has been executed.
z=Device address +8
Command Messages Comments
Command Messages Comments
90 60 02 FF Returned when the command format is different
or when a command with illegal command
parameters is accepted.
Syntax Error
Command Buffer Full Indicates that two sockets are already being
used (executing two commands) and the
command could not be accepted when received.
90 60 03 FF
Command Cancelled 90 6y 04 FF
(1:Socket No.)
Returned when a command which is being
executed in a socket specified by the cancel
command is canceled. The completion message
for command is not returned.
No Socket 90 6y 05 FF
(1:Socket No.)
Returned when no command is executed in a
socket specified by the cancel command, or
when an invalid socket number is specified.
Command not executable 90 6y 41 FF Returned when a command cannot be executed
due to current conditions. For example, when
commands controlling the focus manually are
received during auto focus.
(1:Socket No.)
Command Message Comments
Network Change z0 38 FF Issued when power is being routed.