Sony 3-869-888-16 (1) Security Camera User Manual


 
104
Chapter 5 Settings
Network Address
Enter the camera’s IP address in this text box.
This setting does not appear when configuring multiple cameras
simultaneously.
HTTP Port
Enter the HTTP port number necessary to access the camera.
Timeout (sec)
Enter an access timeout for the camera in seconds.
Use Proxy
If you are using a proxy server to access the camera, select this check box. If you
select this check box, configure the address and port number of the proxy server.
SNT Settings
These settings appear when the selected camera is from the SNT series.
Configure settings specific to SNT models.
Specify the channel if the camera is registered as an SNT with multiple
channels. Furthermore, to register the cameras of each channel, click [Add
Channel] and register them as new cameras.
Camera
Select a connected analog camera.
For SNT-V304 : A camera cannot be specified.
Note
The “New Protocol 1” to “New Protocol 5” options that appear for the
SNT-V704 are scheduled for future use.
Channel
Select the channel to use.
For SNT-V704 or SNT-V304:
Select from Channel 1, Channel 2, Channel 3, and
Channel 4.
For SNT-V501 : Fixed to Channel 1. This cannot be modified.
Video Settings
Configure the monitor and recording settings for images captured by the
camera.
Mount Angle
Configure the angle for camera images. Select from 0 degrees, 90
degrees, 180 degrees, and 270 degrees.
Caution
VMF and Video Motion Detection (Camera) do not support the 90- and
270-degree mount angles. When using VMF or Video Motion Detection
(Camera), always use the 0- or 180-degree mount angles.
Video Codec
Set the video codec for the camera. Select from JPEG or MPEG 4.
FPS
Specify the image frame rate for the camera.
Resolution
Specify a resolution for images imported from the camera.
For some cameras, the resolution used will differ for NTSC and PAL. For
details, refer to “Camera Resolution Details” (page 173).