Basic Setups for the Switcher
Chapter 3 Preparations
To disable the select button
Use this function if you are not using any of select buttons 1 to 12.
On menu page 922, turn the F1 control to select the number of the select button
to be disabled under “XPT BTN.” Turn the F4 control to set “INHIBIT”
(inhibition) to “On”. The selected button will no longer operate even if you press
the button.
When the setting is complete
Press the CAM mode button or SW mode button to exit menu mode.
If you change the setting, “Save setup data? [PAGE] (yes) or [EXIT] (no)”
appears on the display panel. Press the PAGE button to store the data.
To add a frame synchronizer to the input video signal (menu page 925)
If the input video is an asynchronous signal, it can be synchronized using the
frame synchronizer built in the switcher.
1
Display menu page 925.
For the procedure for displaying the menu, see “Menu Operation” on page
46.
When menu page 922 is displayed, pressing the PAGE button three times
displays menu page 925.
2
Turn the F1 control to select the video input signal for which you wish to
change the FS (frame synchronizer) setting under “SIGNAL.”
SDI1 to SDI4: to select an SDI signal input from the device connected to
the SDI IN 1 to 4 connectors at the rear of the Processor Unit (When the
BRSA-20HSD1 HD/SD-SDI input board is installed in the IN1 card
slot, the input channels increase to eight and the selectable items also
increase to “SDI8.”)
The signal name set under “RENAME” on menu page 921 is displayed
under “NAME” of this menu. Since the items under “SIGNAL” and
“NAME” are changed relative to each other, you can select the signal from
the signal name by turning the F2 control instead of the F1 control.
3
Turn the F3 control to set “FS.”
On: to add a frame synchronizer to the selected video input signal
Off: not to add a frame synchronizer to the selected video input signal
When the setting is complete
Press the CAM mode button or SW mode button to exit menu mode.
If you change the setting, “Save setup data? [PAGE] (yes) or [EXIT] (no)”
appears on the display panel. Press the PAGE button to store the data.
Note
INPUT
SIGNAL NAME FS 5/6
FS
SDI1 (4 chars.) On 925
Note