4
Chapter 4 Adjustments and Settings for Recording4-38
2 Set the F-RUN/SET/R-RUN switch to SET.
3 Set the DATA DISPLAY switch to U-BIT.
4 Set the user bits by using the SHIFT and ADVANCE buttons.
SHIFT: Selects a digit to set. Each time you press the button, the
flashing digit moves one column to the right.
Pressing this button while holding down the HOLD button
moves the flashing digit one to the left.
ADVANCE: Increments the value of the flashing digit.
Pressing this button while holding down the HOLD button
decrements the flashing digit.
Hexadecimal digits A to F are displayed as follows:
Hexadecimal ABCDEF
Display AbCdEF
Resetting a modified numeric value to 00:00:00:00
To reset a numeric value that was modified, press the RESET
button.
5 Set the F-RUN/SET/R-RUN switch to F-RUN or R-RUN,
corresponding to the desired time code run mode.
The specified user bits will be recorded for both LTC and VITC.
To store the user bits in memory
The user bits setting (apart from the real time) is automatically retained
in memory even when the power is turned off.