Sony HKCU-904 Camera Accessories User Manual


 
1-22 (E)
HDCU-900 MM
Page 6
System Diag (2/3) Display
No. Contents
1 State of camera cable connection (Open/Short/NG)
2 Existence of data from the camera (__/Wait/Sense/OK)
__ : The communication with the camera cannot
be established.
Wait : The communication with the camera is being
waited.
Sense :The communication with the camera is being
established.
3 State of the power supply of the camera (ON/OFF)
4 State of connection to the camera (OK/NG
*4
)
5 State of cable connection of the RCP/CNU connector of
the rear panel of the unit (Open/Connect)
6 Existence of the data from the RCP/CNU connector of
the rear panel of the unit (__/Wait/Sense/OK)
__ : The communication with the equipment
connected to the RCP/CNU connector cannot be
established.
Wait : The communication with the equipment connect-
ed to the RCP/CNU connector is being waited.
Sense :The communication with the equipment connect-
ed to the RCP/CNU connector is being estab-
lished.
7 State of the power supply of the RCP/CNU connector of
the rear panel of the unit (OK/NG)
*4 : When power of the camera is supplied from the outside too, NG
appears.
Page 7
System Diag (3/3) Display
No. Contents
1 Setting state of the intercom 1ch of the camera side
(ENG/PROD)
2 Setting state of the intercom 2ch of the camera side
(ENG/PROD)
3 Gain and control state of the microphone circuit of the
camera side (Remote/Local)
Page 8
AT Diag Display
Displays the details of self-diagnosis of the AT-141 board
of the unit.
No. Contents
1 Setting state of the S603 switch on the AT-141 board
(1.001/1.000)
*5
2
Setting state of the S601 and S602 switches on the AT-
141 board (SD Local/SD Remote/HD Local/HD Remote)
*5
3 Setting state of delay amount (setting of the S120 switch
on the AT-141 board) when converting the format of the
HD-SDI signal (1Frame/90H)
*5
4 Setting state of the S110 switch on the AT-141 board
(Local/Remote)
*5
5 Setting state of the S111 switch on the AT-141 board
(Local/Remote)
*5
6 Setting state of the S103-4 switch on the AT-141 board
(Recall/HD ANA)
*5
7 State of the operation mode of the AT-141 board
(Normal/Test)
*5 : For details, refer to Section 1-5-1, AT-141 Board of Settings of
Switches and Controls on Boards of the separate Installation and
Maintenance Manual.
* System Diag 2/3 *
Camera Cable Connect
Data OK
Power ON
Sense OK
RCP/CNU Calble Connect
Data OK
Power OK
1
2
3
4
5
6
7
* System Diag 3/3 *
Intercom
Camera CH1 PROD
MIC ON
CH2 PROD
MIC ON
Camera MIC Gain
CH1 60dB Local
CH2 60dB Local
1
2
3
* AT Diag *
System Frequency 1.001
Ref.H Phase SD Local
HD-SD DLY 90H
Ret Setting Local
Marker Setting Local
WFM Mode HD ANA
CCU Mode Normal
1
2
3
4
5
6
7
1-12. Character Display Function