Sony HKCU-904 Camera Accessories User Manual


 
3-12 (E)
HDCU-900 MM
3-4-2. SD-SDI Input VCO Free-run
Adjustment
Measure : Frequency counter
Note
After replacing IC601 on the RC-86 board only, perform
this adjustment.
Preparation
. Board extension : RC-86 board (front side)
. S110 (L-8)/AT-141 LOCAL
. S101 (L-8)/AT-141 All OFF
. COR601 (A-3)/RC-86 FREE RUN (Short between 2-
pin and 3-pin.)
. Connect the measure as shown in the following figure.
. After turning on the power, wait for 10 minutes at least
and start adjustment.
Adjustment Procedure
Measuring point : TP603 (C-1)/RC-86
Adjusting point : 1RV601 (B-3)/RC-86
Specifications : 27.0 ±0.2 MHz
Note
After finishing the adjustment and waiting for 10 minutes
at least, confirm that each specification is satisfied.
If the specifications are not satisfied, perform the adjust-
ment again.
Setting after Adjustment
. After finishing the adjustment, return the switches to the
original setting.
. COR601 (A-3)/RC-86 NORMAL
(Short between 1-pin and 2-pin.)