Chapter 5 Connections and Preparations 5-17
Setting the Pre-Reverse Time
(HSR-2/2P only)
With the HSR-2/2P, set the pre-reverse time to see the
latest recorded scenes while recording using the
Playback During Recording function.
When you press the PLAY (PRE REVERSE PLAY)
key during recording, the point of the preset time
before the current time is located on the hard disk, then
playback starts from that point.
The default pre-reverse time is 5 minutes. You may
set it in a range from 1 to 99 minutes in units of
minute.
Set the pre-reverse time at PRE REV TIME in the
Function Control menu.
1 Highlight FUNCTION CONTROL MENU (or
display FuncMenu) of the top menu by pressing
the V or v key, then press the b key.
The Function Control menu is displayed.
SETUP MENU
FUNCTION CONTROL MENU
AUTO REW : ON
POWER ON REC : OFF
BEEP : ON
STILL : FRAME
PRIORITY : PLAY
PRE REV TIME : 5 MIN
FUNCTION LEVEL SET
PASSWORD SET
2 Highlight PRE REV TIME by pressing the v key,
then press the b key.
The setting display for the pre-reverse time
appears.
PRE REVERSE TIME SET
PRE REVERSE TIME : 5MIN
ABORT : MENU KEY
DATA SET : SET KEY
3 Set the pre-reverse time by pressing the V or v key.
4 Press the SET key to register your setting.
A message “NOW SAVING” is displayed, and the
new setting is stored in nonvolatile memory.
To restore the previous setting
Before pressing the SET key, press the MENU key.
A message “ABORT!” is displayed, and the previous
setting is restored.