TANDBERG D50503.02 Digital Camera User Manual


 
TANDBERG Intern MXP Edge Install Kit
D50503.02
If installed, u
nscrew
the two
thumbscrews
from underneath the
codec shelf to
remove the codec.
Remove the codec.
(If codec is installed.)
Unscrew the three (3) bolts
t
hat hold the codec shelf to
the pole and remove shelf.
Set bolts aside for STEP 2.
Place
the
Precision
HD
Camera shelf into
position as shown.
Be sure to feed
the cables through
the hole.
Use the same
three (3) bolts
from STEP 1 to
secure the new
PHD Camera
shelf to the
pole.
Use two (2) screws to
stabilize the new shelf.
Position the
P
HD
Camera onto the
shelf and securely
mount it with
thumbscrew (1)
found underneath
the shelf.
R
emove the
stand on the
Edge codec and p
lace the
Edge
onto the shelf with the
I/O facing up
(be sure that
the power switch is
on the
left –
hand side when facing
the back of the system).
Secure the
Edge c
odec
to the system with the
Edge cover plate
with
five (5) screws.
Connect
the cables as
labeled
. Replace/use
the short cable
for
camera connection by
feed
ing it through the
cable egress and up the
s
mall hole on the shelf
platform.
Use the shorter camera
cable included with the
upgrade kit to connect the
codec and camera
R
emove the ferrite
bead
found with the
longer camera
cable included with
the Edge codec
and attach it to the
new camera cable.
Turn on the power to
the Edge codec.
Your TANDBERG Intern system is now HD ready.
Install cable
cover plate.