© Titan Tool Inc. All rights reserved. 1
Instruction Sheet
For professional use only
Model Number 550-100
S-5 Airless Spray Gun
5000 PSI Maximum Operating Pressure/Stainless Steel Fluid Passages
Safety Precautions
SAVE THESE INSTRUCTIONS – To reduce the risks of re or explosion,
electrical shock, and the injury to persons, read and understand all
instructions included in this manual. Be familiar with the controls and
the proper usage of the equipment.
WARNING – To reduce the risk of fire or
explosion:
1. Donotsprayammableorcombustiblematerialsnear
anopename,pilotlightsorsourcesofignitionsuch
ashotobjects,cigarettes,motors,electricalequipment
andelectricalappliances.Avoidcreatingsparksfrom
connectinganddisconnectingpowercords.
2. Useextremecautionwhenusingmaterialswithaashpointbelow
70ºF(21ºC).Flashpointisthetemperaturethatauidcanproduce
enoughvaporstoignite.
3. Paintorsolventowingthroughtheequipmentisabletoresultin
staticelectricity.Staticelectricitycreatesariskofreorexplosionin
thepresenceofpaintorsolventfumes.Allpartsofthespraysystem,
includingthepump,hoseassembly,spraygunandobjectsinand
aroundthesprayareashallbeproperlygroundedtoprotectagainst
staticdischargeandsparks.Useonlyconductiveorgroundedhigh-
pressureairlesspaintsprayerhosesspeciedbythemanufacturer.
4. Verifythatallcontainersandcollectionsystemsaregroundedto
preventstaticdischarge.
5. Connecttoagroundedoutletandusegroundedextensioncords
(electricmodelsonly).Donotusea3to2adapter.
6. Donotuseapaintorsolventcontaininghalogenatedhydrocarbons.
Suchaschlorine,bleachmildewcide,methylenechlorideand
trichloroethane.Theyarenotcompatiblewithaluminum.Contactthe
coatingsupplieraboutcompatibilityofmaterialwithaluminum.
7. Keepsprayareawellventilated.Keepagoodsupplyoffreshair
movingthroughtheareatokeeptheairwithinthesprayareafree
fromaccumulationofammablevapors.Keeppumpassemblyinwell
ventilatedarea.Donotspraypumpassembly.
8. Donotsmokeinthesprayarea.
9. Donotoperatelightswitches,engines,orsimilarsparkproducing
productsinthesprayarea.
10. Keepareacleanandfreeofpaintorsolventcontainers,rags,and
otherammablematerials.
11. Knowthecontentsofthepaintandsolventsbeingsprayed.Read
allMaterialSafetyDataSheets(MSDS)andcontainerlabels
providedwiththepaintsandsolvents.Followthepaintandsolvent
manufacture’ssafetyinstructions.
12. Placepumpatleast25feet(7.62meters)fromthesprayobjectina
wellventilatedarea(addmorehoseifnecessary).Flammablevapors
areoftenheavierthanair.Floorareamustbeextremelywellventilated.
Thepumpcontainsarcingpartsthatemitsparksandcanignitevapors.
13. Plasticcancausestaticsparks.Neverhangplastictoenclosespray
area.Donotuseplasticdropclothswhensprayingammable
material.
14. Fireextinguisherequipmentshallbepresentandworking.
WARNING – To reduce the risk of skin injection:
HAZARD:
Injection injury – A high pressure fluid stream produced by this
equipment can pierce the skin and underlying tissues, leading
to a serious injury and possible amputation. See a physician
immediately. DO NOT TREAT AN INJECTION AS A SIMPLE CUT.
1. Donotaimthegunat,orsprayanypersonoranimal.
2. Keephandsandotherbodypartsawayfromthedischarge.For
example,donottrytostopleakswithanypartofthebody.
3. Alwaysusethenozzletipguard.Donotspraywithoutthenozzletip
guardinplace.
4. Onlyuseanozzletipspeciedbythemanufacturer.
5. Usecautionwhencleaningandchangingnozzletips.Inthecase
wherethenozzletipclogswhilespraying,
ALWAYSlockguntrigger,shutpumpoff,andreleaseallpressure
beforeservicing,cleaningtiporguard,orchangingtip.Pressure
willnotbereleasedbyturningoffthemotor.ThePRIME/SPRAY
valveorpressurebleedvalvemustbeturnedtotheirappropriate
positionstorelievesystempressure.RefertoPRESSURERELIEF
PROCEDUREdescribedinthepumpmanual.
6. Donotleavetheunitenergizedorunderpressurewhileunattended.
Whentheunitisnotinuse,turnofftheunitandrelievethepressure
inaccordancewiththemanufacturer’sinstructions.
7. High-pressuresprayisabletoinjecttoxinsintothebodyandcause
seriousbodilyinjury.Intheeventthatinjectionoccurs,seekmedical
attentionimmediately.
8. Checkhosesandpartsforsignsofdamage,aleakcaninject
materialintotheskin.Inspecthosebeforeeachuse.Replaceany
damagedhosesorparts.
9. Thissystemiscapableofproducing5000PSI/35MPa.Only
usereplacementpartsoraccessoriesthatarespeciedbythe
manufacturerandthatareratedatorabovethemaximumoperating
pressurerangeoftheairlesssprayer.Thisincludesspraytips,
nozzleguards,guns,extensions,ttings,andhose.
10. Alwaysengagethetriggerlockwhennotspraying.Verifythetrigger
lockisfunctioningproperly.
11. Verifythatallconnectionsaresecurebeforeoperatingtheunit.
12. Knowhowtostoptheunitandbleedpressurequickly.Bethoroughly
familiarwiththecontrols.Pressurewillnotbereleasedbyturning
offthemotor.ThePRIME/SPRAYvalveorpressurebleedvalve
mustbeturnedtotheirappropriatepositionstorelievesystem
pressure.RefertoPRESSURERELIEFPROCEDUREdescribedin
thepumpmanual.
13. Alwaysremovethespraytipbeforeushingorcleaningthesystem.
WARNING – To reduce the risk of injury:
1. Alwayswearappropriategloves,eyeprotection,clothinganda
respiratorormaskwhenpainting.Hazardousvapors–Paints,
solvents,insecticides,andothermaterialscanbeharmfulifinhaled
orcomeincontactwithbody.Vaporscancauseseverenausea,
faintingorpoisoning.
2. Donotoperateorspraynearchildren.Keepchildrenawayfrom
equipmentatalltimes.
3. Donotoverreachorstandonanunstablesupport.Keepeffective
footingandbalanceatalltimes.
4. Stayalertandwatchwhatyouaredoing.
5. Donotoperatetheunitwhenfatiguedorundertheinuenceof
drugsoralcohol.
6. Donotkinkorover-bendthehose.Airlesshosecandevelopleaks
fromwear,kinkingandabuse.Aleakcaninjectmaterialintothe
skin.
7. Donotexposethehosetotemperaturesorpressuresinexcessof
thosespeciedbymanufacturer.
8. Donotusethehoseasastrengthmembertopullorliftthe
equipment.
9. Uselowestpossiblepressuretoushequipment.
10. Followallappropriatelocal,stateandnationalcodesgoverning
ventilation,repreventionandoperation.
11. TheUnitedStatesGovernmentSafetyStandardshavebeen
adoptedundertheOccupationalSafetyandHealthAct(OSHA).
Thesestandards,particularlypart1910oftheGeneralStandards
andpart1926oftheConstructionStandardsshouldbeconsulted.
12. Beforeeachuse,checkallhosesforcuts,leaks,abrasionor
bulgingofcover.Checkfordamageormovementofcouplings.
Immediatelyreplacehoseifanyofthoseconditionsexist.Never
repairapainthose.Replacewithaconductivehigh-pressurehose.
13. Donotsprayoutdoorsonwindydays.
14. Alwaysunplugcordfromoutletbeforeworkingonequipment.
0711 • Form No. 0286934B