© Titan Tool Inc. All rights reserved. 1
Instruction Sheet
2-Finger w/tip 0296236
4-Finger w/tip 0296235
2-Finger w/tip 0296306
2-Finger no tip 0296307
4-Finger w/tip 0296321
4-Finger, no tip 0296322
G-10 XL
High Capacity Spray Gun
Safety Precautions
IMPORTANT SAFETY INSTRUCTIONS
A. SAVE THESE INSTRUCTIONS – To reduce the risks of fire
or explosion, electrical shock, and the injury to persons, read
and understand all instructions included in this manual. Be
familiar with the controls and the proper usage of the
equipment.
B. WARNING – To reduce the risk of fire or explosion:
1. Donotsprayammableorcombustiblematerialsnearanopename,
pilotlightsorsourcesofignitionsuchashotobjects,cigarettes,
motors,electricalequipmentandelectricalappliances.Avoidcreating
sparksfromconnectinganddisconnectingpowercords.
2. Useextremecautionwhenusingmaterialswithaashpointbelow
70ºF(21ºC).Flashpointisthetemperaturethatauidcanproduce
enoughvaporstoignite.
3. Paintorsolventowingthroughtheequipmentisabletoresultin
staticelectricity.Staticelectricitycreatesariskofreorexplosionin
thepresenceofpaintorsolventfumes.Allpartsofthespraysystem,
includingthepump,hoseassembly,spraygunandobjectsinand
aroundthesprayareashallbeproperlygroundedtoprotectagainst
staticdischargeandsparks.Useonlyconductiveorgroundedhigh-
pressureairlesspaintsprayerhosesspeciedbythemanufacturer.
4. Verifythatallcontainersandcollectionsystemsaregroundedto
preventstaticdischarge.
5. Connecttoagroundedoutletandusegroundedextensioncords
(electricmodelsonly).Donotusea3to2adapter.
6. Donotuseapaintorsolventcontaininghalogenatedhydrocarbons.
Suchaschlorine,bleachmildewcide,methylenechlorideand
trichloroethane.Theyarenotcompatiblewithaluminum.Contactthe
coatingsupplieraboutcompatibilityofmaterialwithaluminum.
7. Keepsprayareawellventilated.Keepagoodsupplyoffreshair
movingthroughtheareatokeeptheairwithinthesprayareafree
fromaccumulationofammablevapors.Keeppumpassemblyinwell
ventilatedarea.Donotspraypumpassembly.
8. Donotsmokeinthesprayarea.
9. Donotoperatelightswitches,engines,orsimilarsparkproducing
productsinthesprayarea.
10. Keepareacleanandfreeofpaintorsolventcontainers,rags,and
otherammablematerials.
11. Knowthecontentsofthepaintandsolventsbeingsprayed.Read
allMaterialSafetyDataSheets(MSDS)andcontainerlabels
providedwiththepaintsandsolvents.Followthepaintandsolvent
manufacture’ssafetyinstructions.
12. Placepumpatleast25feet(7.62meters)fromthesprayobjectina
wellventilatedarea(addmorehoseifnecessary).Flammablevapors
areoftenheavierthanair.Floorareamustbeextremelywellventilated.
Thepumpcontainsarcingpartsthatemitsparksandcanignitevapors.
13. Plasticcancausestaticsparks.Neverhangplastictoenclosespray
area.Donotuseplasticdropclothswhensprayingammable
material.
14. Fireextinguisherequipmentshallbepresentandworking.
C. WARNING – To reduce the risk of skin injection:
HAZARD:
Injection Injury - A high pressure uid stream produced by this
equipment can pierce the skin and underlying tissues, leading to a
serious injury and possible amputation. See a physician immediately.
DO NOT TREAT AN INJECTION INJURY AS A SIMPLE CUT.
1. Donotaimthegunat,orsprayanypersonoranimal.
2. Keephandsandotherbodypartsawayfromthedischarge.For
example,donottrytostopleakswithanypartofthebody.
3. Alwaysusethenozzletipguard.Donotspraywithoutthenozzletip
guardinplace.
4. Onlyuseanozzletipspeciedbythemanufacturer.
5. Usecautionwhencleaningandchangingnozzletips.Inthecase
wherethenozzletipclogswhilespraying,
ALWAYSlockguntrigger,shutpumpoff,andreleaseallpressure
beforeservicing,cleaningtiporguard,orchangingtip.Pressurewill
notbereleasedbyturningoffthemotor.ThePRIME/SPRAYvalve
handlemustbeturnedtoPRIMEtorelievethepressure.Referto
PRESSURERELIEFPROCEDUREdescribedinthepumpmanual.
6. Donotleavetheunitenergizedorunderpressurewhileunattended.
Whentheunitisnotinuse,turnofftheunitandrelievethepressurein
accordancewiththemanufacturer’sinstructions.
7. High-pressuresprayisabletoinjecttoxinsintothebodyandcause
seriousbodilyinjury.Intheeventthatinjectionoccurs,seekmedical
attentionimmediately.
8. Checkhosesandpartsforsignsofdamage,aleakcaninjectmaterial
intotheskin.Inspecthosebeforeeachuse.Replaceanydamaged
hosesorparts.
9. Thissystemiscapableofproducing3600PSI/25MPa.Only
usereplacementpartsoraccessoriesthatarespeciedbythe
manufacturerandthatareratedaminimumof3600PSI.Thisincludes
spraytips,nozzleguards,guns,extensions,ttings,andhose.
10. Alwaysengagethetriggerlockwhennotspraying.Verifythetrigger
lockisfunctioningproperly.
11. Verifythatallconnectionsaresecurebeforeoperatingtheunit.
12. Knowhowtostoptheunitandbleedpressurequickly.Bethoroughly
familiarwiththecontrols.Pressurewillnotbereleasedbyturningoff
themotor.ThePRIME/SPRAYvalvehandlemustbeturnedtoPRIME
torelievethepressure.RefertoPRESSURERELIEFPROCEDURE
describedinthepumpmanual.
13. Alwaysremovethespraytipbeforeushingorcleaningthesystem.
D. WARNING – To reduce the risk of injury:
1. Alwayswearappropriategloves,eyeprotection,clothinganda
respiratorormaskwhenpainting.Hazardousvapors–Paints,
solvents,insecticides,andothermaterialscanbeharmfulifinhaledor
comeincontactwithbody.Vaporscancauseseverenausea,fainting
orpoisoning.
2. Donotoperateorspraynearchildren.Keepchildrenawayfrom
equipmentatalltimes.
3. Donotoverreachorstandonanunstablesupport.Keepeffective
footingandbalanceatalltimes.
4. Stayalertandwatchwhatyouaredoing.
5. Donotoperatetheunitwhenfatiguedorundertheinuenceofdrugs
oralcohol.
6. Donotkinkorover-bendthehose.Airlesshosecandevelopleaks
fromwear,kinkingandabuse.Aleakcaninjectmaterialintotheskin.
7. Donotexposethehosetotemperaturesorpressuresinexcessof
thosespeciedbymanufacturer.
8. Donotusethehoseasastrengthmembertopullorlifttheequipment.
9. Uselowestpossiblepressuretoushequipment.
10. Followallappropriatelocal,stateandnationalcodesgoverning
ventilation,repreventionandoperation.
11. TheUnitedStatesGovernmentSafetyStandardshavebeenadopted
undertheOccupationalSafetyandHealthAct(OSHA).These
standards,particularlypart1910oftheGeneralStandardsandpart
1926oftheConstructionStandardsshouldbeconsulted.
12. Beforeeachuse,checkallhosesforcuts,leaks,abrasionorbulging
ofcover.Checkfordamageormovementofcouplings.Immediately
replacehoseifanyofthoseconditionsexist.Neverrepairapainthose.
Replacewithaconductivehigh-pressurehose.
13. Donotsprayoutdoorsonwindydays.
14. Alwaysunplugcordfromoutletbeforeworkingonequipment.
0711 • Form No. 0528927B