Toshiba IK-HR1D Digital Camera User Manual


 
8
IK-HR1D
DC IN 12V
Lens (option)
DVI cable
(not supplied)
DVI terminal
DVI monitor
(not supplied)
DC power supply
(option)
Less than 11 mm [0.433”]
4 1 Standard Connection
4 CONNECTION
When connecting the camera cables, be sure to turn off the CMOS color camera and
any other equipment connected to it.
For DC power supply connecting to DC IN 12V terminal, use UL listed and/or CSA
approved ungrounded type AC adaptor with the specifications described below.
We suggest using a C mount lens accepted mega pixel. When using other lenses,
the best camera performance of this camera may not be obtained.
(For example, low resolution may occur, focus may be lost through the range of
a zoom lens, and flare, ghost may occur.)
Furthermore, in order to avoid damaging the mounting portion of the camera head,
use a lens which has projection dimension from the mounting base of less than
0.433" (11mm.)
Power supply voltage
12V DC
10%
(The maximum voltage must not exceed 16V DC.)
Current rating
More than 830mA
Ripple voltage
Less than 50mV
(
p-p
)
Connector
HR10A-7P-4S by HIROSE electronics Co. Ltd
Pins 1, 2 12V
Pins 3, 4 GND
4 2 Cautions on Connection
* This camera outputs 1080p and 1080i for the video signal. The output mode is
not controlled automatically for the monitor resolution. Please control the
monitor resolution, and switch the mode to "1080p" or "1080i."
If this camera in the output mode does not accept a monitor, the monitor will not
display anything. Refer to the item "5.3 Switching I/P mode" for the operation.
* DVI standard
DVI (Digital Visual Interface) is an interface standard for connecting flat panel
displays (such as liquid crystal display).
DVI connector has three types : DVI-I (digital and analog), DVI-D (digital only),
and DVI-A (analog only) in accordance with a mounting signal conductor.
Please use a DVI cable (not supplied) for an input terminal to connect this
camera.