![](http://pdfasset.owneriq.net/4/4a/44aefbbb-e272-4a12-9280-a5485efc46ff/44aefbbb-e272-4a12-9280-a5485efc46ff-bg21.png)
GX1050 Technical Manual
Page 33
Triggering during the Readout State
o For applications requiring the fastest triggering cycle time whereby the camera
image sensor is exposing and reading out simultaneously, then the User Trigger
signal should be applied as soon as a valid Trigger Ready is detected.
o In this case, Trigger Latency and Trigger Jitter can be up to 1 line time since
Exposure must always begin on an Interline boundary.