Axis Communications Q1604 Security Camera User Manual


 
AXIS Q1604 Network Camera
Technical Specications
DC output
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3.3 V DC
Max load = 50 mA
Digital Input
3
Connect to pin 1 to activate, or leave oating (unconnected)
to deactivate
0 to max 40 V DC
Digital Output
4
Connected to pin 1 when activated, oating (unconnected)
when deactivated. If used with an inductive load, e.g. a relay,
a diode must be connected in parallel with the load, for
protection against voltage transients.
0 to max 40 V DC, open drain,
100 mA
3.3 V max 50 mA
1
2
3
4
Power Connector
2-pin terminal block for power input.
Use a Safety Extra Low Voltage (SELV)
compliant limited power source (LPS)
with either a rated output power
limited to 100 W or a rated output
current limited to 5 A.
DC power input
Audio Connector
3.5 mm audio connectors
(stereo)
123