IP Camera 200 Series Installation | en 19
Bosch Security Systems Installation and Operation Manual AR18-09-B003 | v1.1 | 2010.05
3.5 I/O connector
Figure 3.4 I/O connector pins
– Max. wire diameter AWG 22-28 for both stranded and
solid; cut back 5 mm (0.2 in) of insulation.
– Relay output switching capability: Max. voltage 24 VAC or
24 VDC. Max. 1 A continuous, 12 VA.
– Relay in: Short or +5 VDC activation.
– Alarm input configurable as active low or active high.
Function Pin I/O socket
Relay 1 Relay out
2 Relay out
Alarm input 3 Relay in
4Relay in
1 2 3 4 DC 12V Ethernet Line-out Line-in
5 mm
(0.2 in)
Pin I/O
1
2
3
4
Relay out
Relay in