Q-See QSZ515D Security Camera User Manual


 
Problem Possible reason Solution
No
movement and ima
ge at power-on
1.C
heck the connection of
C power input
2.Turn off power and
check t
he transformer
1.Check the power
connection, make sure
the soc
ket is well connected
2.
Make sure the power outlet is
working
Power-on
shows
mage,
but the
controlle
r doesnot work
1. DIP switch setting
is incorrect
2.RS485 interface is not
connec
ted or is not connected corre
ctly
3.
There is a problem with the
S485 line
1. Refer to setup
instructi
ons, re-
set the DIP switches.
2.Check RS485 interface,
sure
the wires are well connect
ed and in the proper slots
3.Refer to the Appendix:
RS485
Blurred Image Ball case is dirty Clean the ball case
2.
2. Setting of DIP Switches
The internal black case has 8 DIP switches. 8,7,6,5,4,3,2,1 are for Addres
s setting, while 10,9 are for Communication Baud Rate.
In the following table, tag “1” for DIP switch “ON”; tag “0” for DIP switch “off”.
a)
Setting Baud Rate
Baud Rate
Switch # SW2
Baud
Rate
Switch # SW2
BIT 10 9 BIT 10 9
2400bps 0 1 1200bps 1 1
4800bps 1 0 9600bps 0 0
b)
b) Setting Address Code
In a system, decoder includes intelligent speed dome camera and common de
coder. No repeating address codes exist. As you see in the table, “1” for “O
N”, “0” for “OFF”
Address Address Switch (8
Address
Address Switch 8
Code 1 2 3 4 5 6 7 8 Code 1 2 3 4 5 6 7 8
1 1 0 0 0 0 0 0 0 33 1 0 0 0 0 1 0 0
2 0 1 0 0 0 0 0 0 34 0 1 0 0 0 1 0 0
3 1 1 0 0 0 0 0 0 35 1 1 0 0 0 1 0 0
4 0 0 1 0 0 0 0 0 36 0 0 1 0 0 1 0 0
5 1 0 1 0 0 0 0 0 37 1 0 1 0 0 1 0 0
6 0 1 1 0 0 0 0 0 38 0 1 1 0 0 1 0 0
7 1 1 1 0 0 0 0 0 39 1 1 1 0 0 1 0 0
8 0 0 0 1 0 0 0 0 40 0 0 0 1 0 1 0 0
9 1 0 0 1 0 0 0 0 41 1 0 0 1 0 1 0 0
10 0 1 0 1 0 0 0 0 42 0 1 0 1 0 1 0 0
11 1 1 0 1 0 0 0 0 43 1 1 0 1 0 1 0 0
12 0 0 1 1 0 0 0 0 44 0 0 1 1 0 1 0 0
13 1 0 1 1 0 0 0 0 45 1 0 1 1 0 1 0 0
14 0 1 1 1 0 0 0 0 46 0 1 1 1 0 1 0 0
15 1 1 1 1 0 0 0 0 47 1 1 1 1 0 1 0 0
16 0 0 0 0 1 0 0 0 48 0 0 0 0 1 1 0 0
17 1 0 0 0 1 0 0 0 49 1 0 0 0 1 1 0 0
18 0 1 0 0 1 0 0 0 50 0 1 0 0 1 1 0 0
19 1 1 0 0 1 0 0 0 51 1 1 0 0 1 1 0 0
20 0 0 1 0 1 0 0 0 52 0 0 1 0 1 1 0 0
21 1 0 1 0 1 0 0 0 53 1 0 1 0 1 1 0 0
22 0 1 1 0 1 0 0 0 54 0 1 1 0 1 1 0 0
23 1 1 1 0 1 0 0 0 55 1 1 1 0 1 1 0 0
24 0 0 0 1 1 0 0 0 56 0 0 0 1 1 1 0 0
25 1 0 0 1 1 0 0 0 57 1 0 0 1 1 1 0 0
26 0 1 0 1 1 0 0 0 58 0 1 0 1 1 1 0 0
27 1 1 0 1 1 0 0 0 59 1 1 0 1 1 1 0 0
28 0 0 1 1 1 0 0 0 60 0 0 1 1 1 1 0 0
29 1 0 1 1 1 0 0 0 61 1 0 1 1 1 1 0 0
30 0 1 1 1 1 0 0 0 62 0 1 1 1 1 1 0 0
31 1 1 1 1 1 0 0 0
32 0 0 0 0 0 1 0 0 255 1 1 1 1 1 1 1 1
Part 5 PELCO-D Protocol
Data Form 1 beginning position, 10 pieces for data, 1 ending position, invalid
checking point