Elation Professional 05 FOCUS SPOT 250R Camcorder User Manual


 
Focus Spot 250R™
©Elation Professional® 40 Focus Spot 250R™
05Er - Color-wheel error:
The color wheel is not located in the default position after start-up or after a reset
command.
This message will appear after a fixture reset if the color wheel’s magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
06Er - Rotating gobo-wheel error:
The gobo-wheel is not located in the default position after start-up or after a reset
command.
This message will appear after a fixture reset if the gobo wheel’s magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
07Er - Rotating gobo indexing error:
The gobo is not located in the default position after start-up or after a reset command.
This message will appear after a fixture reset if the gobo positioning magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).