By adjusting the switches/potentiometers provided on the side panel, the control functions are available.
AES switch
[Electronic shutter] The camera is
factory-set at the AES switch OFF
and 1/60 sec. shutter speed.
[AES (Automatic Electronic Shutter)]
By setting the AES switch to ON, the
Automatic Electronic Shutter mode
(1/60~1/100,000 sec) is available.
Note: In electronic shutter mode;
*Sufficient brightness is
required.
*The picture will flicker
when shooting under the
illumination produced by
fluorescent lamp.
SENS-UP switch
To increase the sensitivity, set this
switch to ON position.
BLC (Back Light Control) switch
In case the back oighting is too
brighit to shoot the main object
clearly, set this swith to ON position.
ALC LEVEL
Adjust video output level, when
AUTO IRIS switch is DC position.
AUTO IRIS switch
When a DC driven type auto iris lens is used, set this switch to DC position.
When a video feedback type auto iris lens is used, set this switch to VIDEO position.
Vertical sync. phase adjustment potentiometer
Vertical sync. phase adjusting potentiometer is set at the position fully counterclockwise that the delay time of
vertical sync. phase against the phase of power frequency is shortest, when shipped from the factory.
Turning this potentiometer clockwise will make the delay time of vertical sync. Phase against the phase of
power frequency longer.
Use the function control potentiometer if the picture image on a monitor TV may flow when using the
camera in combination with other camera(s) controlled by the Line-Lock synchronization.
In this case, get a proper image by shifting the phase of vertical sync. signal of the camera against that of the
other. If a proper image cannot be obtained even after this adjustment, reset the potentiometer to its original
position, and use the function control potentiometer of the other camera to shift the phase of vertical sync.
signal of other camera.
Caution: Before making adjustment, make sure that cameras have their power supplies connected with the same
polarity. (not 180°apart)
6
6
6
5
4
3
2
1
CAMERA CONTROLS
21 3 4 5 6
AES
ON
OFF
BLC ALC
LEVEL
VIDEODC
SENS-UP AUTO IRIS V-PHASE
TSE270X, TSE272X
21 3 4 5
AES
ON
OFF
BLC ALC
LEVEL
VIDEODC
SENS-UP AUTO IRIS
TSE271X