JAI CV-M300 Security Camera User Manual


 
- 7 -
CV-M300
To use this mode
Set: SW1-4 to ON for ext. trigger shutter
SW1-5 to OFF for field accumulation
SW1-6 to ON for non-interlaced
SW1-1, 2 and 3 to shutter speed
Input: Ext. trigger to pin 5 on 6 pin multi connector.
Ext. HD to pin 6 on 12-pin multi connector. (If used).
75 Ohm termination is done with SW2-1 (HD) on PK8041 board.
Refer to Timing Chart and Cautions on next page.
Detailed switch and jumper setting is described in “7. Mode Setting”.
For connections see “5. Pin Assignment”.
Cautions in the Edge Pre-select Mode.
1. Edge pre-select mode is effective only in non-interlaced, field accumulation mode.
2. The exposure start may delay up to 1H max., when the falling edge of ext. trigger pulse is not
synchronized with the falling edge of ext. HD signal. To avoid this 1H delay and jitter, the falling edge
of the trigger pulse should be synchronized with the HD pulse as shown below. It can be the ext. HD
input or the Internal HD output.
3. The ext. trigger input is TTL level. The duration should be more than 1 H negative going. >64 µsec.
and < 60 msec. The input is AC coupled.
4. If the ext. HD input is TTL level, set SW2-1 OFF for non-terminated. See “7.2 SW2 on PK8041 Board”.
EIA (Non-interlaced / Field accumulation mode)
µ
Edge pre-select mode
(
for non-interlace only
)
EIA : 1H = 63.5µs
TRIG
INT VD
EEN
WEN
EXT HD
INT HD
Effective videoBlanking Blanking
Video out
CCD out
No.10 to 251
Effective pixels
>1H
1.5H 9H
2H 9H
10.5H
0.5H
9H1.5H1H9H
TRIG in1H
20H 242H 20H
Exposure time Exposure time
0.5H
12.5H