JVC GY-HM700CHE Camera Accessories User Manual


 
47
Presetting the Time Code
Time code and user’s bit data generated from the internal
time code generator are recorded.
This section describes how to set [TC Preset] in the [TC/UB]
menu. (A Page 82)
Memo :
When the frame rate setting in [Main Menu]
B
[Record
Set]
B
[Record Format]
B
[Frame & Bit Rate] is
A
50, 25, 24
B
,
settings cannot be made in [Drop]. (
A
Page 71)
You can configure the setting without accessing the [TC/UB]
menu screen. (
A
Page 48)
Required Settings Before Preset
1 Set the [TC GENE.] switch to ARECB or AFREEB.
2 Select the framing mode for the time code generator
(only when the frame rate setting is A60B or A30B).
Set using [Main Menu]B[TC/UB]B[Drop].
(A Page 82)
Memo :
Drop frame/non-drop frame mode
When the frame rate setting in [Main Menu]
B
[Record Set...]
B
[Record Format]
B
[Frame & Bit Rate] is 60 (30), the actual
number of frames per second is approximately 59.94
(29.97). However, the time code processing standard is 60
(30) frames. To make up for the frame number discrepancy,
the drop frame mode (Drop) drops the 00 frame and 01
frame every minute except for minutes that are multiples of
10.
On the other hand, the non-drop frame mode (Non Drop)
does not drop frames and ignores the discrepancy with the
actual time.
Setting Time Code
1 Select [Main Menu]B[TC/UB]B[TC Preset] and press
the Set button (
R). (A Page 82)
The [TC Preset] screen appears.
Memo :
When the [TC GENE.] switch is set to AREGENB, the
parameter is displayed as ARegenerationB and cannot be
selected.
2 Set the time code (hour, minute, second, frame).
Use the cross-shaped button (
H, I) to place the cursor at the
item to set, then the cross-shaped button (
J, K) to change
the values.
Memo :
Press the [USER2] button to reset each digit to
A
0
B
. The
cursor moves to the time digit (left).
3 Check the values and press the cross-shaped button
(R).
The time code is set and the screen returns to [TC/UB].
To cancel the setting, press the [CANCEL] button.
4 Press the [MENU] button.
Returns to the normal screen.
[REC] Preset data in the time code generator operates in
run mode during recording mode. Set this when
recording continous time code in connecting frames.
[FREE] Time code starts to operate in run mode from the
preset time in the time code generator.
[Drop] Sets the run mode of the time code generator to drop
frame mode.
Use this setting when placing emphasis on the
recording time.
[Non
Drop]
Sets the run mode of the time code generator to non-
drop frame mode.
Use this setting when placing emphasis on the
number of frames.
[TC GENE.] Setting Switch
[USER2] Button
[CANCEL] Button
[USER2] Button
[MENU] Button
Set Button (
R)
Cross-
Shaped
Button
(
JKHI)
1
[TC/UB] Menu Screen
Cursor
[TC Preset] Screen
(During drop frame)
During non-drop frame