JVC GR-DV2000U Camcorder User Manual


 
EN75
SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION
17.
The Dissolve function does
not work.
18.
The Picture Wipe and
Dissolve functions do not
work.
19.
The picture wipe function
does not work.
20.
Scene transition does not
go as expected.
17.
The Sepia, Monotone or
Slow Shutter mode of
Program AE with special
effects is activated.
•“WIDE MODE is set to
SQUEEZE or PS-WIDE in
the Menu Screen.
The previously selected
mode of Program AE with
special effects was changed
after the last selected scene
for editing was registered.
18.
The last selected editing
scene is ending.
At the end of the last selected
scene for editing, the Power
Switch was set to OFF.
The power is off.
19.
The Slow Shutter mode is
activated.
•“WIDE MODE is not set to
OFF.
20.
When using Picture Wipe/
Dissolve ( pg. 34), there
is a delay of a fraction of a
second between the previous
record stop-point and the
Dissolve start-point. This is
normal, but this slight delay
becomes especially
noticeable when shooting
fast-moving subject or during
rapid panning.
17.
Turn off Sepia, Monotone or
Slow Shutter before adding
Dissolve to a scene
transition ( pg. 34, 36).
Set WIDE MODE to
CINEMA or OFF mode
( pg. 30).
Make sure you have selected
the mode of Program AE
with special effects you want
before starting editing
( pg. 34, 36).
18.
Select Picture Wipe or
Dissolve before beginning
recording. The effects are
then automatically activated
( pg. 34).
Do not turn off the
camcorders power after
setting Edit-In and Edit-Out
points, as they will all be
erased ( pg. 34).
The camcorder automati-
cally shuts off after 5
minutes have elapsed in the
Record-Standby mode.
Make sure you continue
operations within 5 minutes
after engaging Record-
Standby mode ( pg. 34).
19.
Disengage the Slow Shutter
mode or set WIDE MODE
to OFF before preparing
to use the Picture Wipe
( pg. 30, 34, 36).