Kyocera KD P SERIERS Photo Scanner User Manual


 
KYOCERA Solar, Inc. 800-223-9580 800-523-2329 fax www.kyocerasolar.com
KD MoDules
012113
SPECIFICATIONS
WARNING: Read the instruction
manual in its entirety prior to
handling, installing & operat-
ing Kyocera Solar modules.
Standard Test Conditions (STC)
STC = 1000 W/M
2
irradiance, 25
o
C module temperature, AM 1.5 spectrum*
KD320 KD315 KD245 KD240 KD220 KD215 KD140 KD135
Maximum Power
320W 315W 245W 240W 220W 215W 140W 135W
Number of Cells
80 80 60 60 54 54 36 36
Tolerance
+5% / -3% +5% / -3% +5% / -3% +5% / -3% +5% / -0% +5% / -0% +7% / -0% +7% / -0%
Maximum System
Voltage
600V 600V 600V 600V 600V 600V 600V 600V
Maximum Power
Voltage
40.1V 39.8V 29.8V 29.8V 26.6V 26.6V 17.7V 17.7V
Maximum Power
Current
7.99A 7.92A 8.23A 8.06A 8.28A 8.09A 7.91A 7.63A
Open Circuit
Voltage
49.5V 49.2V 36.9V 36.9V 33.2V 33.2V 22.1V 22.1V
Short Circuit
Current
8.60A 8.50A 8.91A 8.59A 8.98A 8.78A 8.68A 8.37A
Series Fuse
Rating
15A 15A 15A 15A 15A 15A 15A 15A
Length
65.4 65.4 65.4 65.4 59.1 59.1 59.1 59.1
Width
52.0 52.0 39.0 39.0 39.0 39.0 26.3 26.3
Depth
1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8
Weight
60.6 lbs 60.6 lbs 46.3 lbs 46.3 lbs 39.7 lbs 39.7 lbs 27.6 lbs 27.6 lbs
Termination
Method
Locking Plug-in Connectors
*
Subject to simulator measurement uncertainty of +/- 3%.
KYOCERA reserves the right to modify these specifications without notice.
For more detailed specifications, visit www.kyocerasolar.com
NEC 2008 COMPLIANT
UL 1703 LISTED
CERTIFIED IEC61215 ED2 IEC61730 BY JET