Matrix Balanced Fill-Flash operation is possible with F4-Series camera when AI-S or AI-type
Nikkor lenses, Nikon Series E lenses, and lenses for the F3AF are used.
*
2
The above flash modes can be changed to Standard TTL Flash t .
*
3
Only Standard TTL Flash can be performed when the F4’s Metering System is set to Spot
Metering.
*
4
With a G-type Nikkor lens attached to F4-Series, F-801s/N8008s, F-801/N8008 cameras, the A
and M exposure modes cannot be used.
*
5
With F65-Series/N65-Series and Pronea 600i/6i cameras, only Standard TTL Flash can be
performed when the camera’s exposure mode is set to Manual (M)
.
*
6
Center-Weighted Fill-Flash/Spot Fill-Flash is not possible with the F65-Series/N65-Series,
Pronea 600i/6i cameras.
*
7
With a non-CPU Nikkor lens attached to F65-Series/N65-Series or Pronea 600i/6i cameras,
Standard TTL Flash can be performed. (Can only be used with exposure mode set to Manual)
The camera’s exposure meter cannot be used. Set and confirm the aperture using the lens
aperture ring.
1
Set the aperture.
—The method for setting the aperture differs, depending on the lens in
use and the selected exposure mode. (See page 29 on Confirming flash
shooting distance range in TTL Auto Flash t Mode.)
2
Set the flash sync mode.
—Set the camera’s flash sync mode (if available) to front-curtain sync
(Normal).
31
TTL Auto Flash
t
Mode
For cameras in Group II: F4-Series, F65-Series/N65-Series, F-801s/N8008s, F-801/N8008, Pronea 600i/6i
Camera settings
Available flash operation in TTL Auto Flash t Mode
Lens in use*
1
Available flash
operation*
2
Camera’s
exposure
mode
Camera’s
metering
system*
3
Nikkor lenses with a
built-in CPU*
4
Matrix Balanced
Fill-Flash
Desired
mode*
5
Desired
mode
Matrix
Metering
Center-Weighted Fill-
Flash/Spot Fill-Flash*
6
Center-Weighted
Metering
Spot Metering*
3
Nikkor lenses
without a built-in
CPU*
7
Center-Weighted
Fill-Flash/
Spot Fill-Flash*
6
Center-
Weighted
Metering
Spot Metering*
3
Aperture-priority
auto (A)
Manual (M)