Panasonic VQT0A45 Digital Camera User Manual


 
56
!LED
{
GA I N
(
0dB
)
GA I N
(
3dB
)
:
O
:
OF
N
F
O
OF
N
F
O
OF
N
F
OFF
OFF
SHUTTER
:
W
HI TE PRESET
:
EXTENDER
:
FILTER
:
SUPER V
:
25M/50M
:
¢
|
Lamp Displays Inside the Viewfinder
Setting the ! Lamp Display
The items subject to the ! lamp display are selected on the “! LED” SUB menu page on the MAIN
menu screen 2 of 4. (Under the factory setting, the ! LED page is not displayed.) To perform
operations on the ! LED page, either switch the unit to the engineer mode or select the ! LED
page on the USER MENU SEL page 2 of 3 on the MAIN menu screen 4 of 4.
ÁFor details on selecting the engineer mode and display page, refer to Setting Menu Configura-
tion (page 51).
1 Set the MENU SET/OFF switch to the SET position while the SHIFT/ITEM button and UP
button are held down together.
2 Press the PAGE button to display the MAIN menu screen 2 of 4.
3 Repeatedly press the SHIFT/ITEM button to move the cursor to the ! LED position.
4 Press the UP or DOWN button to open the ! LED page.
GAIN (0 dB): This selects whether the ! lamp is to light when the gain is set to a value other than
0 dB.
GAIN (3 dB): This selects whether the ! lamp is to light when the gain is set to a value other than
p3 dB.
SHUTTER: This selects whether the ! lamp is to light when the SHUTTER switch is set to the
ON position.
WHITE PRESET: This selects whether the ! lamp is to light when the white balance memory channel is
set to PRST.
EXTENDER: This selects whether the ! lamp is to light when the lens is in the EXTENDER mode.
FILTER: This selects whether the ! lamp is to light when the filter is set to a position other than
3200K and CLEAR. (1)
SUPER V: This selects whether the ! lamp is to light when SUPER V is set to ON.
25M/50M: This selects whether the ! lamp is to light when the recording format is set to
25 Mbps or 50 Mbps.
5 Repeatedly press the SHIFT/ITEM button to move the cursor to the position of the desired
item.
6 Press the UP or DOWN button at the selected item to select whether the ! lamp is to be set
ON or OFF.
To select ON: Press the UP button.
To select OFF: Press the DOWN button.
To select ON or OFF for another item, repeat steps 5 and 6.
7 When the menu operations are completed, return the MENU SET/OFF switch to the OFF
position.
The setting menu is cleared from the viewfinder screen, and the units current statuses ap-
pear at the top and bottom of the viewfinder screen.