19
Specifications
Power supply:
100 V to 240 V AC, 50/60 Hz
Power consumption:
170 W
(Without CAMERA connected: 32 W)
Capacity for supplying power to a camera:
190 V DC, 0.6 A
indicates safety information.
Operating temperature:
0 °C to 40 °C (32 °F to 104 °F)
Humidity:
10 % to 90 % (no condensation)
Dimensions (Width × Height × Depth):
424 mm × 88 mm × 400 mm
(16-11/16 inches × 3-7/16 inches × 15-3/4 inches)
[Excluding protrusions]
Weight:
Approx. 6.6 kg (14.6 lb)
Video output:
HD-SDI/SD-SDI
4 lines (2 lines shared with picture monitor output *
2
)
Analog composite
1 line (1 line shared with picture monitor output *
2
)
Return input:
HD-SDI/SD-SDI (switched depending on the setting)
2 lines
VBS
1 line
Prompter input:
Analog composite
1 line
Reference input:
Black burst/tri-level *
1
1 line (1 loop-through line)
Microphone output:
0 dBm/600 Ω
2 lines (XLR, 3-pin, male)
Intercom:
Input: –55 dBu to –10 dBu
Output: 100 mW (max.)
(XLR, 5-pin, female)
COMMUNICATION:
Intercom input/output:
(0 dBm, 600 Ω, RTS/4W *
2
)
2 lines (1/2 *
2
)
PGM input (0 dBm/600 Ω)
1 line
Tally input (red, green)
1 input each
ROP interface:
RS-422
1 line, 12 V output
MSU interface:
RS-422
1 line, GPI for control
LAN port:
For computer connection
1 line (10Base-T/100Base-TX, RJ45, crossover cable,
category 5 or above)
*1: The black burst signal and tri-level sync signal of the reference input
are recognized automatically.
*2: Depending on the setting, only one of them can be selected at one
time.
For details on the maximum lengths of connection cables, consult
your dealer.
Note
Inrush current, measured according to European standard EN55103-1,
on initial switch-on: 7 A, after a supply interruption of 5 s: 11 A