13 Configure the alarm settings [Alarm]
The settings relating to alarm occurrences such as settings for the alarm action at an alarm occurrence, the
VMD area settings, and the alarm occurrence notification can be configured on this page.
The “Alarm” page has 3 tabs; the [Alarm] tab, the [VMD area] tab and the [Notification] tab.
13.1 Configure the settings relating to the alarm
action [Alarm]
Click the [Alarm] tab on the “Alarm” page. (®page 42, page 44)
The settings relating to the alarm can be configured in this section. Refer to page 137 and page 140 for further
information about the settings relating to the alarm images and the alarm output terminal.
Alarm
[Terminal 1]
SW355
SW355
SW352
SW352
SW316L
SW316L
SW316
SW316
NP502
NP502
Determine how to use terminal 1.
Off: Not used.
Alarm input: Receives alarms.
Black & white input: Receives the black & white switchover input. (When the input is set to On, the black
& white mode is activated.)
Default: Off
[Terminal 2]
SW355
SW355
SW352
SW352
SW316L
SW316L
SW316
SW316
NP502
NP502
Determine how to use terminal 2.
Off: Not used.
Alarm input
NP502
NP502
: Receives alarms.
Alarm output: Alarm output will be carried out according to the settings for “Alarm output terminal
setup” (®page 140).
Default: Off
[Terminal 3]
SW355
SW355
SW352
SW352
SW316L
SW316L
SW316
SW316
NP502
NP502
SW115
SW115
Determine how to use terminal 3.
Off: Not used.
Alarm input
NP502
NP502
: Receives alarms.
Operating Instructions 135
13 Configure the alarm settings [Alarm]