<ALERT>
The Alert menu applies only to pressurized dome systems.
Sensors strategically placed inside the pressurized dome system continually monitor pressure,
temperature, and dew point. If internal conditions reach unacceptable levels, an alert message
appears on the screen describing the alert condition. Example: If pressure drops below 1 psig,
“LOW PRESSURE” is displayed on the monitor.
The alert message will be repeatedly displayed until the system controller acknowledges the
alert condition by selecting ACK ALERT in the main menu. Once acknowledged, the alert
message changes to the programmed acknowledge action (ACK ACTION). If the alert condition
remains active after a period of time, the alert message reappears on the monitor, restarting the
alert message cycle. This cycle will continue to repeat until the alert condition is resolved.
REPEAT
This setting programs how often an alert message is repeatedly displayed until the system
controller acknowledges the alert condition. The following are the settings for REPEAT:
CONSTANT - The alert message is continuously displayed on the monitor until acknowl-
edged.
15 MIN - The alert message is displayed every 15 minutes for a 15-second duration until
acknowledged.
30 MIN - The alert message is displayed every 30 minutes for a 15-second duration until
acknowledged.
60 MIN - The alert message is displayed every 60 minutes for a 15-second duration until
acknowledged.
REPEAT CONSTANT
ACK ACTION ALWAYS ON
ACTIVATE AUX NO
<CURRENT READING>
RESET ALERT
BACK
EXIT
ALERT