Pelco Manual C2410M-H (10/05) [ 11 ]
REVISION HISTORY
Manual # Date Comments
C2410M 11/99 Original version.
C2410M 1/00 Revised installation instructions. Added FCC notices.
C2410M-A 1/00 Added varifocal lens. Changed format.
C2410M-B 7/00 Added information on dome liner.
C2410M-C 1/01 Added heater element caution.
C2410M-D 7/01 Camera module redesigned, reference ECO 1-7054/7055/7056.
C2410M-E 7/02 Added instructions for fixed lens with auto iris.
C2410M-F 5/03 Revised Installation instructions – bracket and camera assembled at factory. Added iris
level adjustment for fixed lens with auto iris.
C2410M-G 1/04 Added to certifications that all models are suitable for use in environmental air handling
spaces.
C2410M-H 10/05 Revised drawings showing vertical phase and iris level adjustments. Revised switch-setting
descriptions for varifocal lens. Added WEEE statement.
(Design and product specifications subject to change without notice.)
SPECIFICATIONS
General
Operating Temperature: -50° to 122°F (-46° to 50°C)
De-ices to 25°F (-4°C)
Pan/Tilt
Adjustment: Manual; 360° pan; 180° tilt
Construction: Aluminum with steel camera mounting bracket and polycarbonate dome
Finish: White polyester powder coat trim ring with charcoal gray back box
Dimensions
Above Ceiling: 1.75 (H) x 3.50 (W) inches
(4.45 x 8.89 cm)
Below Ceiling: 2.42 (H) x 5.48 (W) inches
(6.15 x 13.90 cm)
Bubble: 3.75-inch diameter
Environment: Low temperature, indoor/outdoor, suitable for use in environmental air
handling spaces
Weight: 1.70 lb (0.77 kg)
Electrical
Input Voltage: 12 VDC or 24 VAC, ±10%
Power Consumption: 13 watts or less
Video Connector: BNC
This equipment contains electrical or electronic components that must be recycled properly to comply
with directive 2002/96/ec of the european union regarding the disposal of waste electrical and electronic
equipment (weee). Contact your local dealer for procedures for recycling this equipment.