3.0 POWER SUPPLY CONSIDERATIONS
Use only the recommended power supplies. Improper
substitutions may damage the camera or cause a shock
or fire hazard.
CC3300-2/CC3300-2X
• The CC3300-2 must always be operated with a 24
VAC, Class 2 (60 Hz) power supply, while the
CC3300-2X must use a 24 VAC (50 Hz) power
supply. Neither power supply is provided. A wall
transformer (as depicted in Figure 2) is an example
of a common power source.
• In the USA, use a power supply which is UL Listed.
In Canada, use a power supply which is CSA Cer-
tified.
• When connecting to the transformer, be sure to
carefully connect each lead to the appropriate ter-
minal. Wrong connections may cause malfunction
and/or damage to video camera.
• Ground the unit or an irregular voltage may be
generated in the AC power cord and may cause
malfunction or damage to the video camera.
• 24 VAC Cameras: Do not exceed 24 VAC in-
put.
Normal input voltage is 24 VAC (50/60 Hz).
The power runs for user-supplied wiring from a 24 VAC
supply to a CC3300-2/CC3300-2X camera should be
within the following limits:
Up to 200 ft (60 m) – 18 AWG (1 mm
2
) or larger.
Up to 325 ft (100 m) – 16 AWG (1.5 mm
2
) or larger
Do not mistakenly attach the
GND terminal on 24 VAC cam-
eras to either of the power ter-
minal inputs. Be sure to use the
grounding lug or screw.
CC3300-3
• The CC3300-3 must be always operated with a 220-
240 VAC, (50 Hz) power supply.
NOTE: The CC3300-3 is supplied with an at-
tached main power cable cord. See illustration