Pelco ES30C Security Camera User Manual


 
C309M-J (9/04) 35
RESET CAMERA
Default Setting
<Camera>
<Line Sync>
<Power Up>
<Wiper>
<Limit Stop>
<Other>
Exit
MAIN MENU
Backlight comp Off
Zoom limit x- -
Reset camera
<Gain/AGC>
<Auto iris>
Next
Exit
Camera Menu
Resetting the camera returns the settings to their defaults.
Models Models Models
ES30C22/ES31C22 ES30CBW18/ES31CBW18 ES30C16/ES31C16
Backlight comp Off Off Off
Zoom Limit No default No default No default
Gain/AGC NTSC PAL
Gain Limit 27 28 29 27
AGC mode N/A N/A N/A Auto
Auto iris NTSC PAL
Mode Auto Auto Auto Auto
Level 66 91 66 57
Peak 16 16 8 16
Low light limit 22 N/A
Shutter speed Auto Auto Auto
Auto focus mode Auto Auto Auto
IR Filter
IR filter mode N/A Auto N/A
Auto IR level N/A Dusk N/A
Sharpness
Auto sharpness On On On
Sharpness No default No default No default
White balance
Auto white bal On On On
R Gain No default No default No default
B Gain No default No default No default
Turning off power does not reset the camera. Camera settings are retained in memory. When the power is turned back on, the settings
will be the same as they were when the power was turned off.
To reset the camera:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Camera.
3. Press the Iris Open button to enter the Camera menu.
4. Position the cursor (>) beside Reset Camera.
5. Press the Iris Open button to reset the camera.