Pelco ICS090-PBI Security Camera User Manual


 
4 C2215M (2/05)
Description
The ICS090-PWI and ICS090-PBI are pendant mount adapters specifically designed for the ICS090
Camclosure
®
integrated camera system. The pendant adapters modify the surface mount Camclosure
domes for pendant installations using a 1.5-inch NPT mount, such as an SWM Series or IWM Series
mount. The ICS090-PWI and ICS090-PBI adapters are also compatible with 0.75-inch NPT pipe and
20 mm threaded conduit.
MODELS
ICS090-PWI Pendant mount adapter, white
ICS090-PBI Pendant mount adapter, black
Installation
To install the ICS090-PWI/ICS090-PBI refer to Figure 1 and Figure 2 and do the following:
1. Install the 1.5-inch NPT mount, 0.75-inch NPT pipe, or 20 mm threaded conduit. Feed the
power and video wiring for the system through the mount/pipe.
2. Feed wires through the center of the mount adapter, and then attach the ICS090-PWI/ICS090-PBI
to the mount/pipe. If you are installing the pendant adapter on a 0.75-inch NPT pipe or 20 mm
threaded conduit place the cosmetic thread cover over the pipe before installing the pendant
adapter (refer to Figure 2).
3. Remove the bubble from the ICS090 Camclosure back box. To remove the bubble from the
ICS090, turn it counterclockwise and lift it from the unit. Place the bubble on a nonabrasive
surface. If the unit is supplied with a liner, remove the liner by gently lifting it from the unit.
Place the liner to the side; it will be reinstalled along with the bubble after the installation has
been completed.
4. Select one of the following methods and connect the video wiring.
BNC – Connect the BNC connector from the Camclosure to a mating BNC connector.
Twisted Pair – Blue wire = Video +
Gray wire = Video -
5. Connect the power wires for the system.
AC operation only:
If you are wiring more than one ICS090 Camclosure system to the same
transformer, connect one side of the transformer to the red wire on all units, and connect the
other side of the transformer to the black wire on all units. Failure to connect all of the units the
same way will cause the cameras to be out of phase with each other and may produce a vertical
roll when switching between cameras.
Voltage Red Wire Black Wire
12 VDC + Ground
24 VAC ~ ~
C2215M ICS090-PWI.book Page 4 Monday, March 14, 2005 3:15 PM