Planet Technology ICA-110W Digital Camera User Manual


 
87
A3: Other possible problems might be due to the network cable.
Try replacing your network cable. Test the network interface of
the product by connecting a local computer to the unit, utilizing a
standard Crossover (hub to hub) Cable. If the problem is not
solved the ICA-110/ICA-110W might be faulty.
Q: Why does the Power LED not light up constantly?
A: The power supply used might be at fault. Confirm that you
are using the provided power supply DC 5V for the ICA-
110/ICA-110W and verify that the power supply is well
connected.
Q: Why does the Link LED not light up properly?
A1: There might be a problem with the network cable. To
confirm that the cables are working, PING the address of a know
device on the network. If the cabling is OK and your network is
reachable, you should receive a reply similar to the following
(…bytes = 32 time = 2 ms).
A2: The network device utilized by the ICA-110/ICA-110W is
not functioning properly such as hubs or switches. Confirm the
power for the devices are well connected and functioning.
A3: The wireless connection might be at fault. In ad-hoc mode
make sure the ICA-110/ICA-110W wireless channel and ESSID
is set to match the PC/Notebook wireless channel and ESSID for
direct communication.
Under infrastructure mode make sure the ESSID on the
PC/Notebook and the ICA-110/ICA-110W must match with the
access point’s ESSID.