Polaroid CSGX36BC3 Digital Camera User Manual


 
D4153659A
12
Trigger signal specification
(1) External trigger input
- Input level Low level: 0 to 0.5V
High level: 2.0 to 5.0V
- Polarity Positive / Negative bipolar
- Pulse width 2us (Minimum)
- Input impedance High impedance
(2) Software trigger Set via the Gigabit Ethernet interface
[Output signal specification]
(1) BUSY_OUT The period that input of the trigger signal is forbidden.
- Output level LVTTL
- Polarity Positive
(2) EXPOSE_OUT The period that this camera exposes.
- Output level LVTTL
- Polarity Positive
Electronic shutter specification
(1) Normal shutter
- PRESET setting 1/100s, 1/250s, 1/500s, 1/1000s, 1/2000, 1/4000,
1/10000, 1/20000s
- Absolute value setting any value is set up in 32-bit floating point form within the range
of 1/20000s to 2s.
(2) Random trigger shutter
- Fixed mode The exposure time depends on the normal shutter speed setting.
- Pulse width mode The exposure time depends on the pulse width.
[Interface specification]
(1) Interface system Gigabit Ethernet IEEE802.3ab (1000BASE-T) conformity
(2) Transmission speed 1Gbps (Maximum)
(3) Video output depends on 7.Functions (1) Format of output image
(4) Protocol GigEVision Camera Interface Standard for Machine Vision
Ver. 1.0 conformity
(5) Conformity Cable Twist pair (Category 5e or over)
(6) Cable length To 100m (at the Unshielded Twist Pair (UTP) cable using)
(7) Recommended cable Oki Electric Cable Co., Ltd
HONDA TSUSHIN KOGYO CO., LTD
High bending resistance shielded Cat5e LAN cable
* Because above recommendation cable is high bending resistance,
maximum length of cable is 40m.
* Contact your dealer / distributor for details
of recommended cable.