Samsung SPD-3700T Security Camera User Manual


 
SPEED DOME CAMERA User’s Manual
70
SPEED DOME CAMERA User’s Manual
71
P (Priority)
:
Set the priority of Alarm Inputs. If more than one alarm is simultaneously activated,
the alarm with the highest priority activates before the others. Once the alarm is canceled, the
next highest priority alarm activates.
SEQ
:
Enables setting up a sequence action for the camera in response to an alarm. Available
sequence actions are Preset, Swing, Group, Tour, Trace and A.Pan.
•Asshowninthepictureabove,theAlarmInputmustbeenteredwiththeOpenandClose
switch signals. Supplying power without entering the signals may damage the product.
Notes
Functional Description Functional Description
Alarm Output
Setting1
1 2 3 4
MD
TRK
Setting2
1 2 3 4
MD
TRK
Timer 1 OFF
Timer 1 OFF
Alarm Setting
Alarm Enable OFF
Alarm Input
Alarm Output
Aux Output
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Status
25.2. Alarm Output
Main Menu/Alarm Setting/Alarm Output
Setting 1,2
:
Enables selecting an Alarm Output method.
- 1, 2, 3, 4, and MD on the menu selection indicate the
alarm input port and motion detection input. Up to 4
alarm inputs can be set for each MD (Motion Detection)
and TRK (Auto Track). 1 alarm output port can be used for
more than 2 alarm inputs along with ones for MD and
TRK.
Timer
:
Enables selecting an Alarm Output method.
- On : Retains an alarm output for a set duration from a
minimum of 1 second to a maximum of 60 hours
upon the alarm occurrence.
- Momentary : Retains an alarm output only until the alarm
is canceled.
The TRK function becomes activated only if the Zone mode
under Zone Settings under Auto Track 2 is set to Alarm.
The Alarm Output is equipped with a relay circuit. The
operation of the alarm output port is as shown in the
diagram below.
•ConnectingthepowerconnectorandGNDincorrectlytotheNC/NOandCOMportsmay
cause a short circuit and fire, damaging the camera.
•Themaximumpowercapacityofthebuilt-inrelayis30VDC/2A,125VAC/0.5A,and
250VAC/0.25A. Operating the camera beyond the capacity may decrease the camera’s
lifespan and damage it.
Notes
NO NO
NC NC
COM COM
Alarm Out OFF Alarm Out ON